Samsung Freedom MIM-E03AN Installation And Maintenance Manual page 24

Air source heat pump with pre-plumbed cylinders & underfloor heating
Hide thumbs Also See for Freedom MIM-E03AN:
Table of Contents

Advertisement

Heating & Hot Water Installation
Cylinder Timer, if you are heating a hot water cylinder
To avoid the cylinder heating being switched off accidentally we normally add 2 on timers a day, one
at 3-00 am and one at 15-00 pm. This stops nuisance tripping, resets the unit after power cuts and
insures the cylinder is hot 24 hours a day. We don't normally set any off times.
To set the cylinder up as above:
1.
Press Timer button once,
2.
Press right, daily is flashing, daily is the hot water time clock, press right
Press right 1 will show,
3.
Press right,
4.
5.
On systems with a 12-hour clock, pm shows, press up till am and pm shows (24hours).
6.
Press right, hours will be flashing, use up to set hours to 0300.
7.
Press right, minutes will be flashing.
8.
Press right, ON will be flashing.
9.
Press right, the tap will appear,
10.
Press Set
You will return to 2 above. Now repeat with a timer at 15-00 hours.
You can delete or adjust timers by entering timer mode, press Timer once and scrolling up and
down to the timer you want to adjust, just keep scrolling right to the part you want to change and
then use up down to adjust it, then press Set to store. To delete a timer select it with up and down
and press Delete, to save the changes made press the Set button.
When you are finished press ESC.
Systems with Solar cylinder heating
With solar systems its best to switch off the cylinder heating during the day to give the solar the best
chance of heating the cylinder for free.
*If you want to set an off timer at step 8 above, press up to change on to off.