Function and Control
Protection functions are the same as those in any other mode.
3 Other Control
3.1 Timer function
General timer and clock timer functions are compatible by equipping remote controller with different functions.
3.1.1 General Timer
Timer ON can be set at unit OFF. If selected ON time is reached, the unit will start to operate according to previous setting status. Time
setting range is 0.5-24hr in 30-minute increments.
Timer OFF can be set at unit ON. If selected OFF time is reached, the unit will stop operation. Time setting range is 0.5-24hr in
30-minute increments.
3.1.2 Clock Timer
Timer ON
If timer ON is set during operation of the unit, the unit will continue to operate. If timer ON is set at unit OFF, upon ON time reaches the
unit will start to operate according to previous setting status.
Timer OFF
If timer OFF is set at unit OFF, the system will keep standby status. If timer OFF is set at unit ON, upon OFF time reaches the unit will
stop operation.
Timer Change
Although timer has been set, the unit still can be turned on/off by pressing ON/OFF button of the remote controller. You can also set the
timer once again, and then the unit will operate according to the last setting.
If timer ON and timer OFF are set at the same time during operation of the unit, the unit will keep operating at current status till OFF
time reaches.
If timer ON and timer OFF are set at the same time at unit OFF, the unit will keep off status till ON time reaches.
Each day in future, the system will operate according to preset mode till OFF time reaches and stop operation till ON time reaches. If
ON time and OFF time are the same, OFF command will prevail.
3.2 Auto Button
If this button is pressed, the unit will operate in AUTO mode and indoor fan will operate at auto speed; meanwhile, the swing motor
operates. Press this button again to turn off the unit.
3.3 Buzzer
Upon energization or availably operating the unit or remote controller, the buzzer will give out a beep.
3.4 Sleep Function
In SLEEP mode, the unit will automatically select appropriate sleep curve to operate according to different temperature setting.
3.5 Turbo Function
This function can be set in cooling mode to quickly cool the room.
3.6 X-FAN Function
This function can be set in COOL or DRY mode.
3.7 Automatic Control of Fan Speed
In this mode, the indoor fan will automatically select high, medium or low speed with the change of ambient temperature.
3.8 Up & Down Swing
After energization, up & down swing motor will firstly have the horizontal louver rotate anticlockwise
to position 0 to close air outlet.
If swing function has not been set after startup of the unit, turn clockwise to level position L in other modes.
If swing function is set when starting up the unit, the horizontal louver will swing between L and D.
There are 7 swing status of horizontal louver: Positions L, A, B, C and D, swing between L and D
and stop at any position between L and D (angles between L and D are equiangular).
Upon turning off the unit, the horizontal louver will close at position 0. Swing function is available
only when swing function is set and indoor fan is operating.
Note: If the position is set between L and B, A and C or B and D by remote controller, the horizontal
louver will swing between L and D.
3.9 Display
3.9.1 Operation and Mode Icons
Upon energization, the unit will display all icons. Under standby state, running indicating mark is displayed in red. If the unit is started
by remote controller, running indicating mark gives off light; meanwhile, the mark of current running mode will be displayed (mode LED:
cooling and dry mode). If the light button is turned off, no mark will be displayed.
3.9.2 Display of Nixie Tube on Indoor Unit
When energized & started for the first time, the indoor unit defaults to displaying current set temperature (16 ~ 30 ℃ ). When set
temperature display is set by remote controller, it will display set temperature; when room temperature display is set, it will display room
temperature. After that, when operating the remote controller for other settings, the temperature display method will keep original.
When operating the remote controller during room temperature display, the set temperature will be displayed for 5 seconds firstly and
then room temperature display returns.
o
0
L
A
B
C
D
17