(A)
(B)
GPH
8 bar
11 bar
2,25
7,4
8,8
2,50
8,2
9,8
3,00
9,9
11,8
3,50
11,5
13,7
4,00
13,2
15,7
4,50
14,8
17,6
5,00
16,5
19,6
5,50
18,1
21,5
6,00
19,8
23,5
6,50
21,4
25,5
(1) light oil: density 0,84 kg/dm
(C)
D587
Kg/h
(1)
14 bar
17 bar
20 bar
10,0
11,1
11,9
11,2
12,4
13,4
13,4
14,8
16,1
15,6
17,3
18,8
17,8
19,8
21,5
20,1
22,2
24,0
22,3
24,7
26,8
24,5
27,2
29,5
26,8
29,7
32,2
29,0
32,0
34,5
3
- viscosity 4,2 cSt/20 °C - temperature 10 °C
INSTALLATION
BOILER PLATE (A)
Drill the combustion chamber locking plate as
shown in (A). The position of the threaded holes
can be marked using the thermal screen sup-
plied with the burner.
SECURING THE BURNER TO THE
BOILER (B)
Protective fettling in refractory material 8) must
be inserted between the boiler's fettling 9) and
the blast tube 7).
This protective fettling must not compromise the
extraction of the blast tube.
- Remove the screws 2) from the two slide
- Remove the screw 1) fixing the burner 4) to the
- Withdraw the combustion head 10) from the
Secure flange 5) to the boiler plate interposing
the supplied gasket 6). Use the 4 screws provid-
ed after having protected the thread with an-
tiscruffing products (high-temperature grease,
compounds, graphite). The burner-boiler seal
must be airtight.
CHOICE OF NOZZLE (C)
The burner complies with the emission require-
ments of the EN 267 standard.
In order to guarantee that emissions do not vary,
D1751
recommended and/or alternative nozzles speci-
fied by the manufacturing company in the In-
struction and warning booklet should be used.
erations.
22 bar
company and inadequate regular maintenance
12,4
may result into emission limits non-conforming
14,0
to the values set forth by the regulations in
16,8
force, and in extremely serious cases, into
19,8
potential hazards to people and objects.
22,6
The manufacturing company shall not be liable
25,1
for any such damage arising from nonobser-
28,1
vance of the requirements contained in this
30,9
manual.
33,7
36,0
The nozzle must be chosen from among those
listed in table (C).
The deliveries of the 1st and 2nd stages must be
contained within the value range indicated on
page 7.
7
bars 3).
flange 5).
burner 4).
Warning: It is advisable to replace nozzles
!
every year during regular maintenance op-
Caution: The use of nozzles other than
!
those specified by the manufacturing
IMPORTANT
Use nozzles with a 60° hollow or semi-
solid spray angle.
In case of moisture due to narrow combus-
tion chamber, it is possible to use nozzles
providing 45° full-cone spray angle.