Safeline SL2 Manual page 13

Table of Contents

Advertisement

OTHER CODES
Indicator mode
Voice communication time-out
Reset active alarm automatically
Auto answer
Unit number
Detect dial tone
Receipt to alarm receiver with
P100 protocol
Break on new alarm
Alarm button delay time
Alarm button type
Change password
Simulate an alarm event
Tone/Voice detection
Battery capacity check
Reset to default settings
Configuration
CODE DATA COMMENTS
*78*
- #
0 = Standard
1 = Strictly EN81-28
2 = Strictly single EN81-28
*79*
- #
1 - 20 minutes. Standard = 8 min
*80*
#
0 = OFF
1 = ON (Default)
*81*
- - #
No of signals before SafeLine answers incoming call. Can
be set from 00-16 (Default = 02, 00=Unit will not answer).
*82*
- #
Program Unit number 1-9 (Default = 0)
*83*
- #
0 = Off
1 = On (Default)
Set to off if SafeLine has problem to detect the dial tone.
*84*
- #
Select which message(s) to send to the alarm receiver
at an alarm call.
0 = None (Default)
1 = Start of alarm
2 = Start+end of alarm
*86*
- #
Disconnects a call longer than 60 seconds at new
activation of the alarm button and calls the next emer-
gency call number.
0 = OFF
1 = ON (Default)
*87*
- - #
Delay time from pressing the alarm button until acti-
vating the alarm.
00-25 seconds. (Default = 05)
*89*
- #
0 = Normally-open contact, NO (Default)
1 = Normally-closed contact, NC
*91*
- - - - # Change password (default=0000)
*94*
- #
Triggers an alarm event after programming is terminated.
1 = Emergency call
2 = Test alarm
3 = Battery failure
4 = Microphone/Loudspeaker failure
5 = Receipt on voice call
6 = Maintenance
7 = Main unit power failure
8 = Stuck button alarm
*95*
- #
0 = Off (Default)
1 = On
*98*
- - #
When the battery capacity goes over the set value (10-
25%) the SL2 will send a battery alarm. Recommended
for lead-acid batteries 0,8 - 2,3 Ah
00 = inactive
[10, 15, 20, 25] = percentage the battery capacity has
dropped, (default =20)
99 = reset battery reference, in case the battery has
been replaced.
*99*
- #
1 = Factory default
2 = Default P100(The following codes will be set):
*21*0#, *22*0#, * 27*03#, *80*1#, *84*1#, *88*1#
3 = Default CPC(The following codes will be set):
*21*3#, *22*3#, *27*03#, *80*1#, *84*1#, *88*1#
4 = Default VOICE(The following codes will be set):
*21*1#, *22*1#, * 27*03#, *80*1#, *84*1#, *88*1#
5 = Default France (The following codes will be set):
*21*1#, *22*1#, *23*1#, *24*1#, *27*3#, *31*4#,
70*1#,*80*0#, *84*2#, *89*1#, *98*20#
13
SL2 v. 2.01 EN

Advertisement

Table of Contents
loading

Table of Contents