Samsung AM080xXV Series Service Manual page 254

Outdoor unit
Table of Contents

Advertisement

AM080/100/120/200FXWA
K3 (Number of press)
1 time
K4
(Number of press)
1 time
2 times
Target frequency (Compressor 1)
3 times
Target frequency (Compressor 2)
4 times
5 times
6 times
Discharge temperature (Compressor
7 times
Discharge temperature (Compressor
8 times
IPM temperature (Compressor 1)
9 times
IPM temperature (Compressor 2)
10 times
CT sensor value (Compressor 1)
11 times
CT sensor value (Compressor 2)
12 times
13 times
14 times
15 times
TOP temperature (Compressor 1)
16 times
TOP temperature (Compressor 2)
17 times
18 times
19 times
20 times
21 times
22 times
23 times
24 times
25 times
Current frequency of the compressor
26 times
Current frequency of the compressor
27 times
28 times
Address of master indoor unit
29 times
When you install the product, optional function for outdoor unit must be set in compliance with installation conditions.
SW version, View mode 2 and address of the indoor unit, press and hold for three seconds to enter the K4.
(Information will be displayed in following order. Main-Hub-INV1-INV2 FAN1-FAN2-EEP-Automatically assigned address -
manually assigned address.)
View mode 2
K4
KEY operation
(Number of press)
1
TIME
Main version
2
TIMES
HUB version
3
TIMES
Water HUB version
4
TIMES
Inverter1 version
5
TIMES
Inverter2 version
6
TIMES
EEPROM version
The device receives
7
TIMES
automatic address
The device receives
8
TIMES
a manual address
Samsung Electronics
KEY operation
Intialize (Reset) setting
KEY operation
Outdoor unit model
High pressure (MPa)
Low pressure (MPa)
Suction temperature
COND OUT temperautre
Temperature of liquid pipe
Water temperature
EVI inlet temperature
EVI outlet temperature
Main EEV 1 step
Main EEV2 step
EVI EEV step
HR EEV step
-
Suction 2 temperature
Temperature of control box
KEY operation
Main version
HUB version
Water HUB version
Inverter1 version
Inverter2 version
EEPROM version
The device receives
automatic address
The device receives
a manual address
Display on segment
Same as initial state
Display on segment
SEG 1
AM120FXW → Off, 1, 2
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
When master indoor unit is not set → BLANK, N, D
S
When indoor unit No.1 is set as master indoor unit →0, 0, 1
T
Display on Page
Page 1
Main
HUB
HUB2
INV1
INV2
EEPROM
AUTO
Indoor unit : "A","0"
MANU
Indoor unit : "A","0"
SEG2, 3, 4
120 Hz → 1, 2, 0
120 Hz → 1, 2, 0
1.52 MPa → 1, 5, 2
0.43 MPa → 0, 4, 3
87 °C → 0, 8, 7
87 °C → 0, 8, 7
87 °C → 0, 8, 7
87 °C → 0, 8, 7
2 A → 0, 2, 0
2 A → 0, 2, 0
-42 °C → -, 4, 2
-42 °C → -, 4, 2
-42 °C → -, 4, 2
-42 °C → -, 4, 2
-42 °C → -, 4, 2
-42 °C → -, 4, 2
-42 °C → -, 4, 2
-42 °C → -, 4, 2
2000 steps → 2, 0, 0
2000 steps → 2, 0, 0
300 steps → 3, 0, 0
2000 steps → 2, 0, 0
-
120 Hz → 1,2,0
120 Hz → 1,2,0
-42 °C → -, 4, 2
-42 °C → -, 4, 2
Page 2
Version(ex. 1412)
Version(ex. 1412)
Version(ex. 1412)
Version(ex. 1412)
Version(ex. 1412)
Version(ex. 1412)
SEG1,2
SEG3,4
Adress(ex. 07)
MCU : "C","1"
SEG1,2
SEG3,4
Adress(ex. 15)
8-13