rF04 – Remove wireless associations (from thermostat only.)
o See
"How to connect your
1G – Configuration Menu
All customisable settings can be found here. The menu takes you through each setting in turn. Use
+/- keys to adjust settings, press OK to confirm and move onto next setting.
See
above
for how to reach configuration menu.
CF01 – Correcting the measured temperature
o This allows you to manually adjust for any discrepancy between the temperature
read by the thermostat and the actual temperature in the room.
o Use +/- keys to adjust from -5 °C to 5 °C.
CF02 – Temperature displayed in auto mode
o 0 = Set temperature (default)
o 1 = Actual temperature
CF04 – Thermostat control type
o 0 = Chrono-proportional (PI) control (default)
o 1 = On/Off control
CF05 – Display energy saving settings
o 0 = Display switches off after 10 seconds if nothing is pressed
o 1 = Displays switches off between midnight and 5am
o 2 = Display always on (default)
CF06 – On/off symbol displayed in standby mode
o 0 = Not displayed
o 1 = Display (default)
CF07 – Backlight
o 0 = Disabled
o 1 = Enabled (on when using thermostat, switches off after a timer) (default)
CF08 – Open window detection function
o 0 = Disabled (default)
o 1 = Enabled
o NOTE – this function only works if you have paired the thermostat with a
door/window magnetic contact which tells the thermostat it has opened.
CF09 – Presence detection function
o 0 = Disabled (default)
o 1 = Enabled
o NOTE – this function only works if you have paired the thermostat with a motion
detector
o If your motion detector senses absence, it will do the following after set periods of
absence:
panels" for full guide.
i.e. if the thermostat senses 24 °C but the actual temperature is 20 °C, set
CF01 to -4 °C to adjust down.
Thermostat checks temperature at time intervals and then tells heaters to
turn on/off.
Thermostat tells heaters to turn on/off as soon as it detects the temperature
dropping below/above the set level.
1.5 hour -> Temperature of current setting is reduced by -1.5 °C
3.5 hour -> Temperature of current setting is reduced by -3.5 °C
17/04/2019 – TPF-Eco version u111