A : Minimum Ducted Hood Height
B : Minimum Recirculating Hood Height
C : Maximum Hood Height
D : Minimum Ducted Ceiling Height
E : Minimum Recirculating Ceiling Height
F : Maximum Ceiling Height
Standard Duct Cover
ZAN
ZSA
ZRV
A
27"
28"
23"
B
31"
32"
27-
"
1/2
C
48"
45"
42-
"
1/2
D
89" (7' 5")
90" (7' 6")
85" (7' 1")
E
93" (7' 9")
94" (7' 10")
89-
" (7' 5-
1/2
118" (9' 10")
115" (9' 7")
F
112-
" (9' 4-
1/2
Extension Duct Cover
ZAN
ZSA
ZRV
A
43"
46"
41"
47"
B
50"
46"
C
80"
81"
80"
D
105" (8' 9")
110" (9' 2")
103" (8' 7")
E
109" (9' 1")
112" (9' 4")
108" (9')
F
151" (12' 7")
150" (12' 6")
150" (12' 6")
DUCTING
A minimum of 6" round duct must be used to
maintain maximum air flow efficiency.
Always use rigid type metal ducts only. Flexible
A
n .
ducts could restrict air flow by up to 50%.
m i
B
n .
m i
x . C
Use calculation worksheet to compute total duct
m a
work (Page 5).
ALWAYS, when possible, reduce the number of
transitions and turns. If a long duct run is required,
i n .
a x .
" m
increase duct size from 6" to 7" or 8".
2 6
" m
3 4
If turns or transitions are required: Install as far
away from duct opening and as far apart between
the two transitions as possible.
Minimum mount height between range top to hood
bottom should be no less than 26".
"
Maximum mount height should be no higher than
34".
It is important to install the hood at the proper
mounting height. Hoods mounted too low could
result in heat damage and fire hazard; while hoods
mounted too high will be hard to reach and will
loose performance and efficiency.
If available, also refer to range manufacturer's
height clearance requirements and recommended
ZRO
hood mounting height above range. Always check
26-
"
your local codes for any differences.
1/2
30-
"
1/2
Duct cover extension kit available for ceiling
47-
"
1/2
heights up to 12 feet. Turn to page 22 for part
88-
" (7' 4-
")
1/2
1/2
number and ordering information.
")
92-
" (7' 8-
")
1/2
1/2
1/2
")
117-
" (9' 9-
")
DAMAGE-SHIPMENT / INSTALLATION:
1/2
1/2
1/2
• Please fully inspect unit for damage before
installation.
ZRO
• If the unit is damaged in shipment, return the
41"
unit to the store in which it was bought for
45"
repair or replacement.
77"
• If the unit is damaged by the customer, repair
103" (8' 7")
or replacement is the responsibility of the
107" (8' 11")
customer.
• If the unit is damaged by the installer (if other
147" (12' 3")
than the customer), repair of replacement must
be made by arrangement between customer
and installer.