Napoli
ZNA-M90BS
ZNA-E42BS
Model number:
Serial Number:
JUL12.0401 © Zephyr Corporation
www.zephyronline.com
C
Airflow Control Technology
TM

Advertisement

Table of Contents
loading

Summary of Contents for Zephyr Napoli ZNA-M90BS

  • Page 1 Napoli ZNA-M90BS ZNA-E42BS Model number: Airflow Control Technology Serial Number: JUL12.0401 © Zephyr Corporation...
  • Page 2 www.zephyronline.com...
  • Page 3 SAFETY NOTICE ..............LIST OF MATERIALS ............INSTALLATION Ducting Calculation Sheet ........Mounting Height & Clearance ........ Ducting Options ............Hood Specifi cations ........... Mounting the Hood 9-10 ............. Ductless Recirculating ..........FEATURES & CONTROLS Touch Controls ..........12 User Interface..........13 MAINTENANCE Hood and Filter Cleaning .........
  • Page 4: To Reduce The Risk Of Fire Electric Shock, Or Injury To Persons, Observe The Following

    www.zephyronline.com READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a.
  • Page 5: Operation

    ZNA-M90BS, ZNA-E42BS - 215 Watts, 3.5 Amps Power consumption shown above is the default power specs. Hoods with Zephyr’s proprietary Airfl ow Control Technology (ACT) enabled will consume less power. See wiring diagram at the end of this manual for more information.
  • Page 6: Hardware Package Contents

    www.zephyronline.com MODELS: ZNA-M90BS, ZNA-E42BS PARTS SUPPLIED (2) Thick Trim Pieces (2) Top Duct Covers (1) Top Support Frame (2) Thin Trim Pieces (1) Bottom Support Frame (2) Bottom Duct Covers (1) 8” round damper (pre-installed) Front of Hood (1) Hood Body Cut-Out Shaded Area (1) Paper ceiling template (4) 3W LED Light Bulbs...
  • Page 7 Equivalent number Equivalent number Duct pieces Duct pieces length x used T otal length x used T otal 3- 1/ 4” x 10” 1 Ft. 6”- 8” Round 30 Ft. Rect., wall cap straight with damper 7” Round, 1 Ft. 6”- 8”...
  • Page 8: Damage - Shipment/Installation

    www.zephyronline.com ALWAYS, when possible, reduce the number of transitions and turns. If a long duct run is required, increase duct size from 8” to 10”. If turns or transitions are required: Install as far away from duct opening and as far apart between the two transitions as possible.
  • Page 9 WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid metal ductwork only. Fasten all connections with sheet metal screws and tape all joints w/ certifi...
  • Page 10 www.zephyronline.com ” 13/16 ” 13/16 STANDARD min. ducted - 32” min. recirc. - 36 ” max. - 50” Z1C-01NA min. ducted - 49” min. recirc. - 53 ” max. - 80” ”, 41 ” 7/16 15/16 ” 9/16 SIDE FRONT ”...
  • Page 11 CAUTION: At least two installers are required due to the weight and size of the hood. Bottom Support Frame (secures to top of blower housing) back Key Holes Ceiling Joists Wood Blocking Top Support Frame front - facing controls FIG. C Support Frame Arm FRONT FIG.
  • Page 12 www.zephyronline.com Cable Lock A cable locking connector (not Top Support Frame supplied) might be required by local codes. Check with local requirements and codes, purchase and install appropriate connector if necessary. Top Duct Covers Thick Trim Piece Cable Lock Thin Trim Piece Bottom Duct Covers FIG.
  • Page 13 Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed. When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust from cooking are drawn and fi ltered by a set of optional charcoal fi lters. The air is then purifi ed and re- circulated back within the home.
  • Page 14 www.zephyronline.com Display (speed level, delay off, filter clean/change,clean air) Power / Delay Off clean mesh filter clean air replace charcoal filter Lights On/Dim/Off Adjust 6 Speed Levels 1 Power / Delay Off Button Power Button Function Button will turn power on and off for entire hood (fan and lights). - Hood will remember the last speed and light level it was turned off at.
  • Page 15 Mesh Filter Clean Indicator (always enabled) - After 30 hours of fan usage the Graphic and words “ clean mesh filter ” will illuminate indicating it is time to clean the mesh filters. Graphic and words will remain illuminated until reset. - To reset: With hood off, hold the Button for three seconds, after three seconds the Graphic and words “...
  • Page 16: Surface Maintenance

    www.zephyronline.com SURFACE MAINTENANCE: Clean the hood surface periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent or steel wool/scouring pads which will scratch and damage surface. For heavier soil use liquid degreaser. After cleaning it is recommended that you use non-abrasive stainless steel polish/cleaners, to polish and buff out the stainless luster and grain.
  • Page 17 TROUBLESHOOTING PROCEDURES FOR NAPOLI ISLAND Issue Cause What to do After installation, 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s the unit doesn’t power is ON. work. 2. The power line and the cable locking connector 2.
  • Page 18 Some local codes limit the maximum amount of CFM a range hood can move. ACT allows you to control the maximum blower CFM of hoods with Zephyr’s DCBL Suppression System without the need for expensive make up air kits. ACT enables the installer to easily set the maximum blower speed to one of three most commonly specifi...
  • Page 20 www.zephyronline.com Model: ZNA-M90BS/E42BS Voltage: 120V 60Hz Power consumption Total: Max. 215W @ 3.5A Lamp: Max. 3Wx4 5A 250V Fan: Max. 203W AC-N AC-L THERMALLY PROTECTED ON/OFF DOWN LAMP Power consumption shown for default 715 CFM blower confi guration ACT 590 CFM - Fan Max. 130W @ 1.8A ACT 440 CFM - Fan Max.
  • Page 21 DESCRIPTION PART# Replacement Parts Light Bulb 3W LED (each) Z0B-0032 Aluminum Mesh Filter (each) 50200027 Optional Accessories Recirculating Kit ZRC-00NA Replacement Charcoal Filter (each) Z0F-C002 Extension Duct Cover Z1C-01NA To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.8368...
  • Page 22 Zephyr Corporation (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or work- manship as follows: Three Year Limited Warranty for Parts and LED lamps: For three years from the date of your original purchase of the Products, we will provide, free of charge, Products or parts to replace those that failed due to manufacturing defects.
  • Page 23 Napoli ZNA-M90BS ZNA-E42BS Numéro de modèle : _________________ Numéro de série : _________________ JUL12.0401 © Zephyr Corporation Airflow Control Technology...
  • Page 24 www.zephyronline.com...
  • Page 25 MISE EN GARDE DE SÉCURITÉ ......LISTE DU MATÉRIEL ............INSTALLATION Feuille de calcul pour le conduit ......Espace libre et hauteur de montage ....Options d’installation pour le conduit ....Spécifi cations de la hotte ......... Montage de la hotte 9-10 ...........
  • Page 26 LISEZ ET CONSERVEZ CES INSTRUCTIONS www.zephyronline.com AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE OU DE DÉCHARGE ÉLECTRIQUE, N’UTILISEZ PAS CET APPAREIL AVEC UN TABLEAU DE COMMANDE À SEMI-CONDUCTEURS. AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE, DE DÉCHARGE ÉLECTRIQUE OU DE BLESSURE, RESPECTEZ CES CONSIGNES : a.
  • Page 27: Exigences Électriques

    ZNA-M90BS, ZNA-E42BS – 215 Watts, 3,5 Ampères Consommation ci-dessus est des spécifi cations d’alimentation par défaut. Hottes avec Zephyr technologie écoulement d’air de contrôle exclusif (ACT) a permis consomme moins d’énergie. Voir le schéma de câblage à la fi n de ce manuel...
  • Page 28: Pièces Non Fournies

    www.zephyronline.com MODÈLES : ZNA-M90BS, ZNA-E42BS PIÈCES FOURNIES (2) Pièces d’habillage larges (2) Pièces de recouvrement (1) Cadre de fixation supérieur supérieures pour le conduit (2) Pièces d’habillage minces (1) Cadre de fixation inférieur (2) Pièces de recouvrement inférieures pour le conduit (1) Registre circulaire de 8”...
  • Page 29 Equivalent number Equivalent number Duct pieces Duct pieces length x used T otal length x used T otal 3- 1/ 4” x 10” 1 Ft. 6”- 8” Round 30 Ft. Rect., wall cap straight with damper 7” Round, 1 Ft. 6”- 8”...
  • Page 30 www.zephyronline.com La hauteur de montage minimale ne devrait pas être moins de 26”. La hauteur de montage maximale ne devrait pas outrepasser 34”. Il est important d’installer la hotte à la hauteur de montage adéquate. Les hottes installées trop basses pourraient être endommagées par la chaleur en plus de présenter des risques x .
  • Page 31 AVERTISSEMENT DE RISQUE D’INCENDIE N’évacuez ou ne terminez JAMAIS l’échappement du conduit dans les espaces entre les murs, les vides sanitaires, le plafond, le grenier, ou le garage. Tous les échappements doivent être dirigés à l’extérieur de la maison, à moins que l’option de reprise d’air ne soit utilisée. N’utilisez que des conduits en métal pour cloison simple.
  • Page 32 www.zephyronline.com ” 13/16 ” 13/16 STANDARD Min. avec conduit - 32” Min. avec reprise d’air - 36 ” max. - 50” Z1C-01NA Min. avec conduit - 49” Min. avec reprise d’air - 53 ” max. - 80” ”, 41 ” ”...
  • Page 33 ATTENTION : Compte tenu du poids et des dimensions de la hotte, au moins deux installateurs sont nécessaires. Cadre de fixation inférieur (est fixé à la partie supérieure du boîtier du ventilateur) Encoches en trou Solives de plafond Bloc de bois Cadre de fixation Devant –...
  • Page 34 www.zephyronline.com Raccord de câble Un raccord de câble (non inclus) Cadre de fixation pourrait également être exigé par les supérieur normes et réglementations locales. Informez-vous des exigences et des normes locales. Achetez et installez le connecteur approprié si nécessaire. Pièces de recouvrement Pièce d’habillage large supérieures Pièce d’habillage mince...
  • Page 35 La confi guration de reprise sans conduit a été conçue pour les applications où il est impossible d’installer un conduit d’aération. Lorsque transformée, la hotte fonctionne comme une hotte de reprise d’air plutôt que comme un système d’évacuation d’air. Les vapeurs et fumées de cuisson sont aspirées et fi ltrées par un ensemble optionnel de fi ltres à charbon. L’air est ensuite purifi...
  • Page 36 www.zephyronline.com Touche de mise en Affichage (vitesse, arrêt automatique, nettoyage/changement des filtres, purification d’air) marche/arrêt automatique clean mesh filter clean air replace charcoal filter Lumières : Allumer/Veilleuse/Éteindre Choix de six vitesses 1-Touche de mise en marche/arrêt automatique Fonction de mise en marche - La touche permet d’allumer et d’éteindre la hotte (ventilateur et lumières).
  • Page 37 Indicateur de nettoyage des filtres à tamis (toujours en fonction) - Après 30 heures d’utilisation du ventilateur, le symbole et les mots « clean mesh filter » s’illuminent, indiquant qu’il est temps de nettoyer les filtres à tamis. Le symbole et les mots restent illuminés jusqu’à la réinitialisation de la fonction. - Pour réinitialiser : Lorsque la hotte est éteinte, appuyez et tenez la touche enfoncée pendant trois secondes.
  • Page 38 ENTRETIEN DES SURFACES: Nettoyez régulièrement les surfaces de la hotte avec de l’eau savonneuse chaude et un chiffon de coton propre. N’utilisez pas de détergent abrasif ou corrosif, de laines d’acier ou de tampons à récurer; ils égratigneront et endommageront les surfaces. Pour les taches plus tenaces, utilisez du produit dégraissant liquide.
  • Page 39 PROCÉDURES DE DÉPANNAGE POUR LA HOTTE NAPOLI ISLAND Problème Cause Solution Après 1. Le bloc d’alimentation n’est pas allumé 1. Assurez-vous que l’alimentation du disjoncteur l’installation, et de l’appareil est allumée l’appareil ne 2. La ligne électrique et le raccord de câble ne sont 2.
  • Page 40 ACT vous permet de contrôler le maximum CFM de les hottes avec le système de répression DCBL à partir de Zephyr sans avoir besoin de coûteux kits pour l’air de remplacement. ACT permet à l’installateur de régler facilement la vitesse maximale du ventilateur à l’un des trois les plus couramment prescrits niveaux de CFM;...
  • Page 42: Schéma De Circuits

    SCHÉMA DE CIRCUITS MOTEUR DEL DEL DEL Modèle : ZNA-M90BS/E42BS 120V 60Hz Tension : BRANCHEMENT DES COMMANDES Consommation d’énergie Max. 215W @ 3.5A Max. 3Wx4 Lampe : 5A 250V Max. 203W Ventilateur : AC-N AC-L CCI DES COMMANDES BOÎTIER PROTÉGÉ THERMIQUEMENT HAUT LAMPE ON/OFF...
  • Page 43 DESCRIPTION DE PIÈCE Pièces de remplacement Ampoule DEL 3W (chaque) Z0B-0032 Filtre à tamis en aluminium (chaque) 50200027 Accessoires optionnels Ensemble de reprise d’air ZRC-00NA Filtre à charbon de remplacement (chaque) Z0F-C002 Ensemble de prolongement de recouvrement de conduit Z1C-01NA Pour commander des pièces, visitez-nous en ligne au www.zephyronline.com ou communiquez avec nous par téléphone au 1-888-880-8368...
  • Page 44 Zephyr Corporation (désigné aux présentes sous le nom de « nous ») garantit au premier acheteur (désigné aux présen- tes sous le nom de « vous » ou « votre ») de produits Zephyr (les « Produits ») que lesdits produits sont exempts de défauts de fabrication ou de main-d’œuvre selon les conditions suivantes :...

This manual is also suitable for:

Napoli zna-e42bs

Table of Contents