Summary of Contents for Siemens Cerberus PRO FS720
Page 1
FS720 Cerberus™ PRO Fire detection system Components / Spare parts / Repair parts Building Technologies A6V10227652_i_en_-- 2016-05-30 Control Products and Systems...
About this document ................5 Stand-alone fire control panels ............7 Fire control panels FC721 (1-loop) in housing (Eco) .......7 Expansion for fire control panels FC721 ..........8 2.2.1 RS485 module ..................8 2.2.2 RS232 module ..................8 2.2.3 Housing Eco (empty) ................8 2.2.4 Housing Standard (empty) ..............9 2.2.5 Auxiliary power supply ................9 2.2.6...
About this document About this document Purpose This document describes all components, spare parts and repair parts for the Cerberus PRO FS720 fire detection system. This document is revised and expanded on a continuous basis. Scope This document contains information on all available components for IP4. Target groups This document arranges itself to all persons.
Page 6
23.10.2015 Edition IP6: Formal update, Operating units, Operating add- A6V10227652_i_en_-- 30.05.2016 Correction of edition IP6: Date corrected Download The current issue documentation and photos can be found in the Siemens Intranet. https://workspace.sbt.siemens.com/content/00001123/default.aspx (STEP, Asset Portal) Building Technologies A6V10227652_i_en_-- Fire Safety...
Stand-alone fire control panels Stand-alone fire control panels Fire control panels FC721 (1-loop) in housing (Eco) FC721-ZZ Fire control panel (1L) Part no. S54400-C32-A2 FC721-YZ Fire control panel (1L, 1LED) Part no. S54400-C32-A3 Expansion see chapter 2.2 FC721-ZZ Accessories see chapter 2.3 Product data sheet A6V10203220 The FC721 in housing (Eco) is compact prefabricated fire control panel with integrated operating unit...
Stand-alone fire control panels Expansion for fire control panels FC721 2.2.1 RS485 module FCA2002-A1 RS485 module (isolated) Part no. A5Q00009923 Application For periphery devices with RS485 interface, e.g. for FAT (GER). Plugged into the back side of the operating unit. –...
Stand-alone fire control panels 2.2.4 Housing Standard (empty) FH7202-Z3 Housing (Standard) Part no. S54400-B70-A1 Application Empty housing for open application, e.g. additional batteries, for operating add-on or for the event – printer. Space for batteries – – 2 x FA2003-A1 (7 Ah) or 2 x FA2004-A1 (12 Ah) or –...
Stand-alone fire control panels 2.2.6 Event printer Event printer FTO2001-A1 Part no. A5Q00010126 Application The event printer can be used in all control panels, terminals or in all empty housings if space is available. Function Including cable for interface, The event printer is a thermal printer that logs alarms, faults and all messages. power supply and paper roll –...
Stand-alone fire control panels 2.3.3 19" mounting kit 19" mounting kit FHA2016-A1 Part no. A5Q00020179 Application To install fire control panels and fire terminals in a 19" third-party housing. Technical data Dimensions (W x H x D) 430 x 100 x 324 mm 2.3.4 Cable kit (communication) FCA2014-A1...
64 fire control panels and fire terminals. The FXS7212 Cerberus-Engineering-Tool permits the system to be adapted to specific customers' – requirements. – Connection of Siemens Danger Management System. FC722-YZ – Suitable for smaller applications, e.g. workshops, hotels, etc. Consists of: Housing (Standard) –...
32 fire control panels and fire terminals. – The FXS7212 Cerberus-Engineering-Tool permits the system to be adapted to specific customers' requirements. Connection of Siemens Danger Management System. – Ideally suited for very large and complex applications, e.g. Hotels, high schools, offices complexes, –...
The FXS7212 Cerberus-Engineering-Tool permits the system to be adapted to specific customers' – requirements. – Connection of Siemens Danger Management System. Ideally suited for large-size applications, e.g. industrial facilities, regional banks, office complexes, – etc. The FC724 can be used by the flexible cross-linking possibilities however also for extensive systems.
64 fire control panels and fire terminals. – The FXS7212 Cerberus-Engineering-Tool permits the system to be adapted to specific customers' requirements. Connection of Siemens Danger Management System. – – Ideally suited for very large and complex applications, e.g. Hotels, high schools, offices complexes, etc.
Networkable fire control panels Expansion for fire control panels FC722, FC723, FC724 and FC726 3.5.1 License keys FCA2033-A1 License key (S1) Part no. S54400-P154-A1 FCA2034-A1 License key (S2) Part no. S54400-P155-A1 FCA2035-A1 License key (S3) Part no. S54400-P156-A1 Application iButton iButton iButton –...
Networkable fire control panels 3.5.4 Fire brigade periphery module FCI2001-D1 Fire brigade periphery module Part no. A5Q00013100 Application For VdS compliant switching to fire department periphery devices (for Germany). Features The module has connections for FBF, FSD, ÜE, FSE, ÖA, KL, tamper alarm FSD. Mounted in the housing on the mounting plate FHA2007-A1, or on the back wall of the housing.
Networkable fire control panels 3.5.7 Repeater (SAFEDLINK) FN2002-A1 Repeater (SAFEDLINK) Part no. S24236-B2502-A1 Application The module is a repeater in the C-WEB. It is used for the extension of the range of the system bus C-WEB. Between 2 stations max. 1 repeater can be used. The distance between network module and repeater may be max.
Networkable fire control panels – Metal screwed cable gland M20 x 1.5 Part no. A5Q00004478 – Back nut Part no. A5Q00004479 Application For surface-mounted feed lines. Technical data Cable gland Dimensions M20 x 1.5 Back nut Dimensions 3.5.8 FCA2007-A1 Card cage (2 slots) Part no.
Networkable fire control panels 3.5.11 RS232 module FCA2001-A1 RS232 module (isolated) Part no. A5Q00005327 Application For periphery devices with RS232 interface, e.g. for event printer FTO2001-A1 or for external matrix printer DL3750+. Plugged into the back side of the operating unit. –...
Networkable fire control panels 3.5.14 I/O card (RT) FCI2007-A1 I/O card (RT) Part no. S54400-A20-A1 Application For the transmission of alarms and faults. The card is mounted in the card cage (5 slots) of the fire control panel FC726. 2x monitored outputs for RT alarm / Horns 1x relay output RT alarm 1x monitored output RT fault 1x relay output RT fault...
Networkable fire control panels 3.5.17 Line card (Interactive) FCL2006-A1 Line card (Interactive) Part no. S54400-A108-A1 Application The Interactive line card is an additional card for Interactive fire detectors with addressable signal evaluation. The line card is required for the migration of Interactive detectors to Cerberus Pro C-NET devices.
Networkable fire control panels 3.5.20 Network components FN2008-A1 Ethernet switch) Part no. S54400-F94-A1 Application The Ethernet switch connects individual clusters via the Ethernet backbone. A second switch can be added if a cluster has more than 512 detectors. With a mounting kit (FHA2029-A1 or FHA2030-A1), the Ethernet switch can be easily integrated into panels or additional housings.
Networkable fire control panels FHA2029-A1 Mounting kit Part no. S54400-B79-A1 Application Mounting kit for Ethernet switch (Comfort) FHA2030-A1 Mounting kit Part no. S54400-B81-A1 Application Mounting kit for Ethernet switch (Large) 3.5.21 Housing Standard und Comfort (empty) FH7202-Z3 Housing (Standard) Part no. S54400-B70-A1 FH7204-Z3 Housing (Comfort)
Networkable fire control panels 3.5.22 Housing Comfort und Large (empty) FH7203-Z3 Housing (Comfort) Part no. S54400-B71-A1 FH7205-Z3 Housing (Large) Part no. S54400-B86-A1 FH7203-Z3 Application FH7203-Z3 – Empty housing for open application, e.g. additional batteries, for operating add-on or for the event printer.
Networkable fire control panels 3.5.23 Operating add-on FCM7205-Y3 Operating add on (1xLED ind.) Part no. S54400-F82-A1 Application To update 24 LED display groups, with one red and one yellow LED each. Inclusive cables and screws for installation. Can be inserted in all empty housings. –...
Networkable fire control panels 3.5.24 Auxiliary power supply FP2003-A1 Power supply kit (70 W) Part no. A5Q00016005 Application Auxiliary power supply to all stations (control panels and terminals). Function Converts mains voltage to system voltage. Monitors mains voltage and batteries. Technical data Mains voltage AC 85…265 V...
Networkable fire control panels Accessories for fire control panels FC722, FC724 and FC726 3.6.1 Key switches FTO2005-C1 Key switch (Kaba) Part no. A5Q00010113 FTO2006-B1 Key switch (Nordic) Part no. A5Q00010129 FTO2005-C1 Features Kaba or Nordic key switch with mounting accessories and key as an option for operating access (operating unit).
Networkable fire control panels 3.6.3 19" mounting kit FHA2016-A1 19" mounting kit Part no. A5Q00020179 Application To install fire control panels and fire terminals in a 19" third-party housing. Technical data Dimensions (W x H x D) 430 x 100 x 324 mm 3.6.4 Cable kit (communication) FCA2014-A1...
Using a fiber-optic backbone (C-WEB/LAN) up to 14 of these clusters with up to 16 panels each can be networked. This topology enables the construction of an EN 54-compliant network with up to 64 fire control panels and fire terminals. Connection of Siemens Danger Management System. – consists of: Housing (Eco) –...
Networkable fire terminal 4.2.6 Network components FN2008-A1 Ethernet switch) Part no. S54400-F94-A1 Application The Ethernet switch connects individual clusters via the Ethernet backbone. A second switch can be added if a cluster has more than 512 detectors. With a mounting kit (FHA2029-A1 or FHA2030-A1), the Ethernet switch can be easily integrated into panels or additional housings.
Networkable fire terminal 4.2.8 Housing (Eco) FH7201-Z3 Housing (Eco) Part no. S54400-B72-A1 Application Empty housing for open use, e. g. additional batteries, power supply, event printer or mimic displays. – Technical data Dimensions (W x H x D) 430 x 398 x 80 mm Color –...
Networkable fire terminal Floor repeater display and floor repeater terminal 4.4.1 Floor repeater terminals FT2010-A1 Floor repeater terminal Part no. A5Q00014104 Product data sheet 009393 Application Small display and operating panel for floors. The floor repeater terminal is a C-NET device and can be operated in loops or stub lines. Features Display of alarms, pre-alarms, technical messages, faults, isolations possible –...
Networkable fire terminal 4.4.2 Floor repeater display Floor repeater display FT2011-A1 Part no. A5Q00017706 Product data sheet 009393 Application Small display panel for floors. The floor repeater display is a C-NET device and can be operated in loops or stub lines. Features Display of alarms, pre-alarms, technical messages, faults, isolations possible –...
Networkable fire terminal Mimic display driver FT2001-A1 Mimic display driver Part no. A5Q00014417 Product data sheet A6V10082691 Application The FT2001-A1 has 2x24 outputs for LED activation for mimic display panels. The mimic display driver is a C-NET device and can be operated in loops or stub lines. Features 2 control outputs for 'Local buzzer' and 'LED operation' –...
Batteries Batteries FA2003-A1 Battery (12 V, 7 Ah, VDS) Part no. A5Q00019353 Features Rechargeable sealed lead-acid battery for emergency power supply. – Must be ordered 2 batteries (system voltage 24 V). – Technical data Dimensions max. (W x H x D) 153 x 103 x 67 mm Battery (12 V, 12 Ah, VDS) FA2004-A1...
Page 40
Batteries FA2007-A1 Battery (12 V, 45 Ah, VDS) Part no. A5Q00022897 Features Rechargeable sealed lead-acid battery for emergency power supply. – Must be ordered 2 batteries (system voltage 24 V). – Technical data Dimensions max. (W x H x D) 200 x 176 x 170 mm FA2008-A1 Battery (12 V, 65 Ah, VDS)
Spare parts Spare parts Cover caps FHA7201-A3 Cover cap (Cerberus) Part no. S54400-B77-A1 Cover with Cerberus label. – Use as spare part. – Cover cap (without print) FHA7202-A3 Part no. S54400-B74-A1 Unlabeled cover. – Use as spare part. – Operating units FCM7215-Y3 Operating unit Part no.
Spare parts Operating add-ons FCM7212-Y3 Operating add-on Part no. S54400-F88-A1 Operating add-on (complete base) without accessories. – – Use as spare part. Operating add-on FCM7211-Y3 Part no. S54400-F75-A1 – Operating add-on (complete base) without accessories. Use as spare part. – FCM7205-Y3 Operating add-on Bestell-Nr.
Spare parts Power supply SV 24V-150W Power supply kit (150 W) Part no. V24230-Z6-A4 Power supply (150 W) without accessories. – Use as spare part. – SV 24V-150W Power supply Part no. V24230-Z6-A5 Power supply (150 W) without accessories. – Use as spare part.
Repair parts Repair parts Operating units FCM7201-Z3 Operating unit Part no. A5Q00018923-R Complete operating unit (support base, keypad, MMI main board, CPU module) without accessories. – – Use as repair part only. Operating unit (+LED ind.) FCM7202-Y3 Part no. A5Q00018925-R –...
Repair parts Periphery boards FCI2010-A1 Periphery board (1-loop) Part no. A5Q00031729-R Periphery board (1-loop) without accessories. – – Use as repair part only. FCI2002-A1 Periphery board (2-loop) Part no. A5Q00005545-R – Periphery board (2-loop) without accessories. Use as repair part only. –...
Repair parts Fire brigade periphery module FCI2001-D1 Fire brigade periphery module Part no. A5Q00010145-R Fire brigade periphery module without accessories. – – Use as repair part only. Network module (SAFEDLINK) FN2001-A1 Network module (SAFEDLINK) Part no. A5Q00012851-R Network module (SAFEDLINK) without accessories. –...
Repair parts Floor repeater terminal and floor repeater display FT2010-A1 Floor repeater terminal Part no. A5Q00014104-R Front part of the floor repeater terminal (cover cap, stick-on labels, keypad) without accessories. – – Use as repair part only. Floor repeater display FT2011-A1 Part no.