Part Three -- Electrical Wiring Schematics And Diagrams; Introduction; Figure 85. Legend - Carrier 69NT40-489-100 Series Operation And Service Manual

Everfresh controlled atmosphere. container refrigeration units
Table of Contents

Advertisement

PART THREE - - ELECTRICAL WIRING SCHEMATICS AND DIAGRAMS

13.1 INTRODUCTION

This section contains the refrigeration unit Schematics and Wiring Diagram. The diagrams are presented as follows:
Figure 85 Provides the legend for use with all figures.
Figure 86 Provides the schematic diagram.
Figure 87 Supplements the Figure 86 and provides schematics for the NatureFRESH.
Figure 88 Provides the wiring diagram.
Sequence of operation descriptions for the various modes of operation are provided in section 4.10, page 48.
SYMBOL
DESCRIPTION (Schematic Location)
AMBS
AMBIENT SENSOR (C- -19)
CB1
CIRCUIT BREAKER - - 460 VOLT (J- -1)
CB2
CIRCUIT BREAKER - - AUTO TRANSFORMER (D- -1)
CCH
CRANKCASE HEATER (T- -11)
CF
CONDENSER FAN CONTACTOR (M- -9, P- -6)
CFS
CONDENSER FAN SWITCH (L- -9)
CH
COMPRESSOR CONTACTOR (M- -8, G- -6, P- -1)
CI
COMMUNICATIONS INTERFACE MODULE (A- -3)
CL
COOL LIGHT (M- -8)
CM
CONDENSER FAN MOTOR (T- -6)
CP
COMPRESSOR MOTOR (T- -1)
CPT
CONDENSER PRESSURE TRANSDUCER (G- -20)
CPDS
COMPRESSOR DISCHARGE SENSOR (A- -18)
CPSS
COMPRESSOR SUCTION SENSOR (D- -18)
CS
CURRENT SENSOR (M- -2)
DHBL
DEFROST HEATER - - BOTTOM LEFT (T- -4)
DHBR
DEFROST HEATER - - BOTTOM RIGHT (T- -4)
DHH
DRAIN HOSE HEATER (L- -13)
DHTL
DEFROST HEATER - - TOP LEFT (T- -4)
DHTR
DEFROST HEATER - - TOP RIGHT (R- -4)
DL
DEFROST LIGHT (M- -12)
DPH
DRAIN PAN HEATER (R- -4)
DPT
DISCHARGE PRESSURE TRANSDUCER (J- -19)
DTS
DEFROST TEMPERATURE SENSOR (C- -18)
DVM
DUAL VOLTAGE MODULE (E- -1)
DVR
DUAL VOLTAGE RECEPTACLE (F- -2)
EF
EVAPORATOR FAN CONTACTOR [HIGH]
(L- -10, M- -10, P- -8)
EM
EVAPORATOR FAN MOTOR (T- -8, T- -9)
ES
EVAPORATOR FAN CONTACTOR [LOW]
(L- -10, M- -10, R- -8)
F
FUSE (C- -7)
FDH
FUSE - - DRAIN LINE HEATER (F- -13)
FH
FUSE - - HUMIDITY (Figure 87)
HA
HUMIDITY ATOMIZER (Figure 87)
HHT
HOSE HEATER THERMOSTAT (J- -13)
HM
HOUR METER (M- -7)
HPR
HUMIDITY POWER RELAY (Figure 87)
HPS
HIGH PRESSURE SWITCH (J- -8)
HPT
HUMIDITY POWER TRANSFORMER (Figure 87)
HR
HEATER CONTACTOR (M- -11, P- -3)
HS
HUMIDITY SENSOR (F- -19)
HST
HOSE HEATER SAFETY THERMOSTAT (G- -13)
SECTION 13
REFRIGERATION CONTROLS
LEGEND
SYMBOL
HTT
HWH
HWP
IC
IP
IRL
PDR
PE
PR
RM
RRS
RTS
SD
SMV
SPT
SRS
ST
STS
TBU
TC
TD
TE
TF
TH
TI
TN
TP
TQ
TR
TRANS
TV
WH
WHTT
WP

Figure 85. Legend

135
DESCRIPTION (Schematic Location)
HEAT TERMINATION THERMOSTAT (F- -11)
HUMIDITY WATER HEATER (Figure 87)
HUMIDITY WATER PUMP (Figure 87)
INTERROGATOR CONNECTOR [FRONT/REAR]
(P- -18, P- -19)
INTERNAL PROTECTOR (E- -7, E- -10, G10)
IN RANGE LIGHT (M- -14)
PUMP DIRECTION RELAY (Figure 87)
PRIMARY EARTH (J- -2)
PROBE RECEPTACLE [USDA]
(E- -18, L- -19, M- -19, N- -219
REMOTE MONITORING RECEPTACLE
(M- -8, M- -12, M- -13)
RETURN RECORDER SENSOR (C- -19 or M15)
RETURN TEMPERATURE SENSOR (B- -19)
STEPPER MOTOR DRIVE (C- -19)
SUCTION MODULATING VALVE (A- -19)
SUCTION PRESSURE TRANSDUCER (H- -19)
SUPPLY RECORDER SENSOR (K- -19)
START - - STOP SWITCH (K- -6)
SUPPLY TEMPERATURE SENSOR (C- -190)
TRANSFORMER BRIDGING UNIT (D- -2)
CONTROLLER RELAY - - COOLING (K- -8)
CONTROLLER RELAY - - WATER
PUMP/ATOMIZER (Figure 87)
CONTROLLER RELAY - - HIGH
SPEED EVAPORATOR FANS
(Figure 86 = K- -10)
CONTROLLER RELAY - - DEFROST (K- -12)
CONTROLLER RELAY - - HEATING (K- -13)
CONTROLLER RELAY - - IN RANGE (K- -3) OR
WATER PUMP REVERSE (Figure 87)
CONTROLLER RELAY - - CONDENSER FAN (K- -9)
TEST POINT (E- -15, G- -9, J- -7, J- -10, J- -11, M- -14,
Figure 87)
CONTROLLER RELAY - - WATER TANK HEATER
(Figure 87)
TRANSFORMER (M- -3)
AUTO TRANSFORMER 230/460 (D- -3)
CONTROLLER RELAY - - LOW SPEED EVAPORATOR
FANS (Figure 86 = K- -10)
WATER HEATER RELAY (Figure 87)
WATER HEATER TERMINATION THERMOSTAT
(Figure 87)
WATER PRESSURE SWITCH (E- -9)
T-305

Advertisement

Table of Contents
loading