Carrier 69NT40-489-100 Series Operation And Service Manual page 127

Everfresh controlled atmosphere. container refrigeration units
Table of Contents

Advertisement

CODE
TYPE
Display/
Cd16
Hours Since Compressor Service
Reset
Display/
Cd17
Hours Since Filter Change
Reset
Cd18
Display
Total Run Hours
Output Codes
Cd19
Display
Air Compressor State (AC)
Cd20
Display
Air Heater State (AH)
Air Heater SSR PWM Valve
Cd21
Display
(AT)
Sample Air Solenoid Valve
Cd22
Display
State (SAV)
Air Calibration Solenoid Valve
Cd23
Display
State (ASV)
Gas Calibration Solenoid Valve
Cd24
Display
State (GSV)
N
Sample Solenoid Valve
2
Cd25
Display
State (NSV)
Oxygen Solenoid Valve State
Cd26
Display
(OSV)
Nitrogen Purity Valve State
Cd27
Display
(NPV)
Drain Valve Solenoid State
Cd28
Display
(DS1 and DS2)
CO
2
Cd29
Display
(CSV)
Cd30
Display
Door Lock Solenoid State (DIS)
Display/
CO
2
Cd31
Select
Calibration Gas
Display/
Cd32
CA Monitor Mode
Select
Cd33
future
future
Display/
Cd34
O
Lower Setpoint Limit Enable
2
Select
TITLE
Input Solenoid Valve State
Concentration in
DESCRIPTION
Records total hours of air compressor run time. Hold the
ENTER key for five seconds to reset to "0".
Displays the number of hours that have elapsed since the
membrane air filters were changed. Records actual hours
(ie. 100 hours is displayed as 100). Hold ENTER key for
five seconds to reset to "0".
Records the total number of operational hours for the CA
system air compressor. Records total hours in increments
of 10 hours. (i.e. 3000 hours displayed as 300)
Displays the current operating status of the air
compressor (ON or OFF).
Displays the current operating status of the air heater (ON
or OFF).
Displays the current operating status of the PWM (Pulse
Width Modulation) signal that is driving the air heater. The
number displayed is a percentage of 100.
Displays the current operating status of the sample air
solenoid valve (OPEN or CLOSED).
Displays the current operating status of the air calibration
solenoid valve (OPEN or CLOSED).
Displays the current operating status of the gas calibration
solenoid valve (OPEN or CLOSED).
Displays the current operating status of the nitrogen
sample solenoid valve (OPEN or CLOSED).
Displays the current operating status of the oxygen
solenoid valve (OPEN or CLOSED).
Displays the current operating status of the nitrogen purity
valve (OPEN or CLOSED).
Displays the current operating status of the drain solenoid
valve − #1 & #2 (OPEN or CLOSED).
Displays the current operating status of the carbon
dioxide solenoid valve (OPEN or CLOSED).
Displays the current operating status of the door interlock
solenoid (OPEN or CLOSED).
Gives the operator the ability to select the purity level of
the CO
gas being used for calibration. (5%, 20%, OFF)
2
Monitor mode provides the ability to monitor CO
levels while the atmosphere inside the container is not
controlled. CO
Zero and O
2
prohibited. (IN/OUT)
future
In the ON position, the O
a default setting of 2.5%.
In the OFF position, the O
a default setting of 2%.
The unit will default with the loading of operational
software.
103
2
Air Calibrations will be
2
lower setpoint limit is 2.5% with
2
lower setpoint limit is 1% with
2
and O
2
T-305

Advertisement

Table of Contents
loading

Table of Contents