iStartek VT900 User Manual

iStartek VT900 User Manual

Gps vehicle tracker
Hide thumbs Also See for VT900:

Advertisement

iStartek GPS Vehicle Tracker
Copy Right © 2018 Shenzhen iStartek Technology Co., Ltd.
File Name
VT900 User Manual
Update
2019-03-6
User Guide V1.3
VT900
Version
Page
1 of 14
1.3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VT900 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for iStartek VT900

  • Page 1 File Name VT900 User Manual Version Update 2019-03-6 Page 1 of 14 iStartek GPS Vehicle Tracker User Guide V1.3 VT900 Copy Right © 2018 Shenzhen iStartek Technology Co., Ltd.
  • Page 2: Table Of Contents

    8.7 Temperature sensor installation (customized) ....................12 8.8 RFID Card Reader installation ........................... 13 8.9 iButton Installation (customized) ........................13 8.10 Magnetic Card Reader installation (customized) ..................... 14 8.11 Ultrasonic Fuel sensor installation ........................14 Copy Right © 2018 Shenzhen iStartek Technology Co., Ltd.
  • Page 3: Copyright And Disclaimer

    With internal memory, VT900 can store GPS coordinates when there is no GPRS/WCDMA connection, or at a specified interval requested by the user. One optional feature of VT900 is that a RS232 port Can connect RFID card reader, magnetic card reader and other Accessories.
  • Page 4: Vt900 Characteristics

    2 LED lights to show GPS/GSM/WCDMA status Antenna External GSM/GPS Antenna Flash Memory 8MB(16192 GPRS/WCDMA location data, 256 SMS) Sensor Vibration sensor 3 digital inputs(1 negative trigger, 2 positive trigger) Inputs/Outputs 1 analog input(0~24V) 2 digital outputs Copy Right © 2018 Shenzhen iStartek Technology Co., Ltd.
  • Page 5: Hardware And Accessories

    GSM Antenna 5.2 Optional Accessories RFID Card Reader RFID Tags iButton Reader iButton Ultrasonic Fuel Sensor Lever Type Fuel Sensor Temperature Sensor Relay Magnetic Card Reader USB Cable 6. Product Appearance Copy Right © 2018 Shenzhen iStartek Technology Co., Ltd.
  • Page 6: Product Use

    7.1 Charge For the first time using the VT900, please connect the DC (positive) and GND (ground) to the 12V or 24V power supply for at least 2 hours to ensure sufficient power. After configuration and testing, install it on the vehicle.
  • Page 7: Vt900 Power On

    Page 7 of 14 place with metal shielding. 7.4 Turn on VT900 Long press the power button for 3-5 sec, or connect to the external power supply, VT900 will turn on. LED operation status: GPS(blue) Input is active Device Turn off or in sleeping mode GPS module is starting up or restarting Flashing(every 0.1 sec)...
  • Page 8: Track By Sms

    7.7 Parameter Configuration Download and install USB cable driver PL2303_Prolific_Driver Connect VT900 to the computer via USB cable. Operating Parameter_Editor configuration software and open the port. Press the on/ off button for 1sec to make device enter Parameter Editor configuration state.
  • Page 9: Platform Location Tracking

    It can be connected with external buzzer alarm, etc. 10-digit analog input, effective input voltage value is 0-24v. Blue Can be used to connect external sensor, such as fuel sensor, etc. Copy Right © 2018 Shenzhen iStartek Technology Co., Ltd.
  • Page 10: Rs232 Port

    Input3 can be connected to the ignition switch of the car to detect the ignition. Input1 or Input2 can be connected to the car door to detect the status of the door. Copy Right © 2018 Shenzhen iStartek Technology Co., Ltd.
  • Page 11: Analog Input (Ad1) Installation

    For example: Analog input connect with fuel sensor,Yellow-green wire of the sensor is connected to the blue wire of VT900. Output voltage of the sensor is 0V when the fuel tank is empty, Output voltage of the sensor is 5V when the fuel Tank is full.
  • Page 12: Output Control Wire Installation

    Customized hardware and software versions are required when the device connect the temperature sensor. Need to customize input2 to1-wire cable, change the AD line to the 5V voltage supply of the temperature sensor, the wiring diagram as follows: Copy Right © 2018 Shenzhen iStartek Technology Co., Ltd.
  • Page 13: Rfid Card Reader Installation

    When the driver starts the vehicle without swiping the authorized card, it is considered to start illegally, and the device will automatically disconnect the oil and electricity and fail to start the vehicle. For related parameter setting instructions, please refer to iStartek SMS protocol and iStartek GPRS Protocol. Copy Right © 2018 Shenzhen iStartek Technology Co., Ltd.
  • Page 14: Magnetic Card Reader Installation (Customized)

    The height measurement range of ultrasonic fuel sensor is fixed at 0~100cm, and the corresponding output voltage range is 0~5V. Formula to calculate oil height:h=(((AD*24)/1024)/5)*100cm If you have any other questions, please send an email to info@istartek.com, we are happy to serve you. Copy Right © 2018 Shenzhen iStartek Technology Co., Ltd.