iStartek VT200-L User Manual

iStartek VT200-L User Manual

4g vehicle gpstracker

Advertisement

Quick Links

iStartek 4G Vehicle GPS Tracker
Copyright Notice ©Shenzhen iStartek Technology Co., Ltd. All rights reserved
File Name
Update
VT200-L User Manual
V1.3
VT200-L User Manual
2021-4-10
Ver.
Page
1 of 18
1.1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VT200-L and is the answer not in the manual?

Questions and answers

Summary of Contents for iStartek VT200-L

  • Page 1 File Name VT200-L User Manual Ver. Update 2021-4-10 Page 1 of 18 iStartek 4G Vehicle GPS Tracker VT200-L User Manual V1.3 Copyright Notice ©Shenzhen iStartek Technology Co., Ltd. All rights reserved...
  • Page 2: Table Of Contents

    8.2.6 RFID Reader Installation ..............................16 8.2.7 iButton Installation ................................18 8.2.8 Ultrasonic Fuel Sensor Installation ..........................19 8.2.9 OBD Reader Installation ..............................21 8.2.10 Speed limiter installation ............................21 Copyright Notice ©Shenzhen iStartek Technology Co., Ltd. All rights reserved...
  • Page 3: Copyright And Disclaimer

    This manual cannot be copied for any purpose, disseminated in any way without the written authorization of iStartek. iStartek shall not be liable for direct, indirect or all losses (including but not limited to economic losses, personal injuries, property and assets) caused by the use or inappropriate use of the product or documents.
  • Page 4: Product Specification

    33hours in power saving mode and 4.5 hours in normal working mode Working temperature -20℃to 80℃ Working humidity 5% to 95% VT200-LCN: LTE-FDD: B1/B3/B5/B8 LTE-TDD: B34/B38/B39/B40/B41 GSM: 900/1800MHz LTE/WCDMA/GSM Bands VT200-LEU LTE-FDD: B1/B3/B5/B7/B8/B20/B28 LTE-TDD: B38/B40/B41 GSM: 850/900/1800/1900MHz Copyright Notice ©Shenzhen iStartek Technology Co., Ltd. All rights reserved...
  • Page 5: Products And Accessories

    AD mode) 1 Analog input(0~36V) 2 Outputs 1 1-wire 1 RS232 1 5V output wire 1 Micro USB 1 Speaker 1 Microphone 5. Products and accessories 5.1 Standard accessories Main Unit Copyright Notice ©Shenzhen iStartek Technology Co., Ltd. All rights reserved...
  • Page 6: Optional Accessories

    5.2 Optional accessories RFID Card Reader RFID Tag iButton Reader iButton Ultrasonic Fuel Sensor Capacitive Fuel Sensor Temperature Sensor 12V/24V Relay OBD Reader USB Cable Buzzer Speaker Microphone SOS Button Copyright Notice ©Shenzhen iStartek Technology Co., Ltd. All rights reserved...
  • Page 7: Product Appearance

    If you need to use the function: Call to reply location, please make sure that the SIM card has the caller ID display function; Please make sure the device is turned off before installing SIM. Remove the waterproof rubber plug; Install the SIM card in the correct direction. Copyright Notice ©Shenzhen iStartek Technology Co., Ltd. All rights reserved...
  • Page 8: Turn On Device

    You will receive a text message with a link to Google maps. Click to open the link to display the current location on Google maps. Please refer to "iStartek GPS Tracker Communication Protocol V1.3" for the description of SMS content and more SMS commands...
  • Page 9: Parameter Configuration

    Download and install the USB cable driver "PL2303_Prolific_Driver". After the device is turned on, connect the VT200-L to the computer via a USB cable, run the "iStartek Parameter Editor_V1.01" configuration software and open the port to enter the parameter configuration state.
  • Page 10: Product Installation

    Digital, can be connected to iButton and temperature sensor, can support up to 8 1-wire Purple temperature sensors. Black DC 5V output, available for temperature sensor and serial port accessories. Green RS232 RX White RS232 TX Speaker- Yellow External speaker, two-way conversation. Copyright Notice ©Shenzhen iStartek Technology Co., Ltd. All rights reserved...
  • Page 11: Device And Accessories Wire Connection

    File Name VT200-L User Manual Ver. Update 2021-4-10 Page 11 of 18 Speaker+ Orange Mic+ Brown External MIC, two-way conversation or listening. Mic- Grey 8.2. Device and Accessories Wire Connection Copyright Notice ©Shenzhen iStartek Technology Co., Ltd. All rights reserved...
  • Page 12: Power/Ground Wire Connection

    8.2.2 Digital inputs installation Input2 can be connected to the vehicle ignition to detect ignition status. Input1 or Input3 can be connected to the car door to detect the state. Copyright Notice ©Shenzhen iStartek Technology Co., Ltd. All rights reserved...
  • Page 13: Analog Input Installation

    The range of analog input AD1 is 0-36V, and the range of AD2 is 0-6.6V. Two voltage output sensors such as fuel sensors can be connected. The wiring connection is as follows: Copyright Notice ©Shenzhen iStartek Technology Co., Ltd. All rights reserved...
  • Page 14 After connected wires, can set the size of the fuel tank (length, width, height), sensor type (capacitive fuel sensor or ultrasonic fuel sensor), liters of fuel stolen, fuel stolen time, low fuel alarm by Parameter Editor. Copyright Notice ©Shenzhen iStartek Technology Co., Ltd. All rights reserved...
  • Page 15: Output Control Wire Installation

    Example: Connect the GPS Tracker analog input to capactive fuel sensor, the yellow-green wire of the sensor are connected to the blue wires (AD) of the VT200-L. When the fuel is empty, the sensor output voltage is 0V, when the fuel is full, the sensor output voltage is 5V Calculate the percentage of remaining fuel: Fuel percentage=(AD/5)*100%=(4.56/5)*100%=91.2%.
  • Page 16: Temperature Sensor Installation

    When the driver does not swipe the authorized card to start the vehicle, it is considered to be illegally started, the device will automatically disconnect the fuel supply and electricity, and the vehicle cannot be started. For related parameter setting instructions, please refer to "iStartek GPS tracker Communication Protocol V1.3". Copyright Notice ©Shenzhen iStartek Technology Co., Ltd. All rights reserved...
  • Page 17 Description: To query the authorization status of the RFID card, you can send the SMS command: 0000,146,123456789,987654321 Query ID number 123456789,987654321, SMS reply 146,123456789:1,987654321:1 Description: 1 means authorized (authorization status: 0 means not authorized, 1 means authorized). Copyright Notice ©Shenzhen iStartek Technology Co., Ltd. All rights reserved...
  • Page 18: Ibutton Installation

    For related parameter setting instructions, please refer to "iStartek GPS tracker Communication Protocol V1.3". After connected wires as above, you can authorize the iButton ID, delete the iButton ID, and query the authorization status of the iButton ID according to the SMS instructions.
  • Page 19: Ultrasonic Fuel Sensor Installation

    V200 L analog input connect to the ultrasonic fuel sensor, the green wire of the sensor is connected to the AD1 blue wire of the VT200-L or the IN3 gray wire (AD2). Example: When the fuel is empty, the sensor output voltage is 0V. With a fuel tank height of 100cm as the standard, then fuel sensor output voltage is 5V when fuel is full.
  • Page 20 Page 20 of 18 Configuration by SMS Command: Set fuel tank parameters through SMS commands 138, 139, 140, and 141. For related parameter setting commands, please refer to "iStartek GPS tracker Communication Protocol V1.3". Send above parameters by SMS commands: Set fuel tank parameters, you can send commands: 0000,138,1,1000,500,1000 Description: 1 is the serial number of the fuel tank.
  • Page 21: Obd Reader Installation

    When connect device with OBD reader, a customized firmware is required. Reading various data of the car can be customized. For related parameter setting instructions, please refer to "iStartek GPS tracker Communication Protocol V1.3". The wiring connection is as follows: 8.2.10 Speed limiter installation...
  • Page 22 After the wires are connected, the speed limit value can be set through the parameter editor or SMS command: 1. Parameter editor settings: VT100 and VT200 series of product set as shown in the figure below: Copyright Notice ©Shenzhen iStartek Technology Co., Ltd. All rights reserved...
  • Page 23 File Name VT200-L User Manual Ver. Update 2021-4-10 Page 23 of 18 Copyright Notice ©Shenzhen iStartek Technology Co., Ltd. All rights reserved...
  • Page 24 0000,212,1,1,22 Set to trigger output 1 after exceeding the set speed value If you have any other questions, please send an email to info@istartek.com, we are happy to serve you. Copyright Notice ©Shenzhen iStartek Technology Co., Ltd. All rights reserved...

Table of Contents