Page 1
Version File Name VT600 User Manual Update 2018-03-17 Page 1 of 11 iStartek GPS Vehicle Tracker VT600 User Manual V1.3 Copyright statement 2018 Shenzhen iStartek Technology Co., Ltd. All right reserve...
VT600 has an inbuilt GPS module to obtain accurate position data. This device utilizes its GSM capability to send position data or vehicle status to tracking server base for tracking and fleet management.
Page 4
Vibration Sensor 3 digital inputs (1 negative trigger, 1 positive trigger, 1 positive or negative optional trigger ) 1 analog input (0-6V) 1 output 1 Mic port 1 USB port Copyright statement 2018 Shenzhen iStartek Technology Co., Ltd. All right reserve...
7.1 Charge When using VT600 for the first time, please connect the device red wire(positive) and black wire(ground) to 12V or 24V power supply for at least 2 hours to ensure sufficient power, install it on vehicle after setting and testing.
2018-03-17 Page 7 of 11 7.4 Device Boot Hold the ON/OFF button for 3-5 seconds or connect an external power supply, VT600 will turn ON. LED indicator lights operation status: GPS LED (Blue) Input is active Device is off or in sleep mode Flashing ( every 0.1 second)
7.7 Parameter Configurations Download and install USB cable drive PL2303_Prolific_Driver. Connect VT600 to PC via USB cable, run Parameter_Editor configuration software and open the port. Press the ON/OFF button for 1sec to let device enter parameter configuration mode. Refer to the Guidelines for the Use of Parameter Configuration Software for more parameter configurations details.
8.3 Digital Input Cable Installation Input3 can be connected to the “ON” switch to detect the ignition. Input2 can be connected to the car door to detect OPEN/CLOSE status. Copyright statement 2018 Shenzhen iStartek Technology Co., Ltd. All right reserve...
AD = 0x00AA = 170 Input Voltage=(AD*6)/1024=(170*6)/1024=0.996V. Take fuel sensor connection as an example, sensor yellow-green cable is connected to VT600 blue cable. The output voltage of the sensor is 0V when the oil is empty and 5V when the oil is full.
Customizing AD cable to 1-wire cable, IN2 to 5V power supply cable of temperature sensor. The wiring diagram is as follows: 8.7 iButton Installation (Customized) Customized hardware and software version when device connect to iButton. Copyright statement 2018 Shenzhen iStartek Technology Co., Ltd. All right reserve...
The height measurement range of the ultrasonic fuel sensor is 0-100cm, and the corresponding voltage output range is 0-5V. The oil calculating formula: h=(((AD*6)/1024)/5)*100cm If you have any questions, please send E-mail to us info@istartek.com, we will serve you wholeheartedly ! Copyright statement 2018 Shenzhen iStartek Technology Co., Ltd. All right reserve...