This manual cannot be copied for any purpose, disseminated in any way without the written authorization of iStartek. iStartek shall not be liable for direct, indirect or all losses (including but not limited to economic losses, personal injuries, property and assets) caused by the use or inappropriate use of the product or documents.
7.1 Recharge When using VT100-L for the first time, please connect the tracker's red wire (positive) and black (ground wire) to a 12V or 24V power supply and charge for at least 2 hours to ensure sufficient power. After configuration and testing are completed, install it on the vehicle.
7.5 Parameter configuration Download and install the USB driver《PL2303_Prolific_Driver》. After the device is turned on, connect the VT100-L to the computer via iStartek USB cable, run the "iStartek Parameter Editor_V1.6" configuration software and open the port to enter the parameter configuration state.
Ver. Update 2022-02-28 Page 11 of 23 For more SMS command functions and parameter configuration, please refer to "iStartek GPS tracker Communication Protocol V1.3" and "iStartek Parameter Editor User Manual V1.5". 8. Product Installation 8.1 Power Cable Function Introduction Color Function DC In (power input), connect to the positive pole of the car battery.
Page 15
Example: Connect the GPS Tracker analog input to capactive fuel sensor, the yellow-green wire of the sensor are connected to the white wires (AD) of the VT100-L. When the fuel is empty, the sensor output voltage is 0V, when the fuel is full, the sensor output voltage is 5V Calculate the percentage of remaining fuel: Fuel percentage=(AD/5)*100%=(4.56/5)*100%=91.2%.
8.4.1 Connect ultrasonic fuel sensor to VT100-L AD Take the analog input of VT100-L connected to the fuel sensor as an example, the green wire of the sensor is connected to the IN1 white wire of VT100-L (Need to configure IN1 as AD1 by parameter editor) or the IN2 orange wire (Need to configure IN2 as AD2 by parameter editor) ①...
Page 20
20 of 23 Configuration by SMS Command: Set fuel tank parameters through SMS commands 138, 139, 140, and 141, 142. For related parameter setting commands, please refer to "iStartek GPS tracker Communication Protocol V1.3". Send above parameters by SMS commands: Set fuel tank parameters, you can send commands: 0000,138,1,1000,500,1000 Description: 1 is the serial number of the fuel tank.
Need help?
Do you have a question about the VT100-L and is the answer not in the manual?