Installer setting

• You can set the product user functions.
• Some functions may not be displayed/operated in some product types.
Function
3 Minutes Delay
Select Temperature Sensor
Dry Contact Mode setting
Central Control address
Pump Test run
Air cooling set temp. setting Adjusting range of 'Setting Air Temperature' in cooling mode
Water cooling set temp.
setting
Air heating set temp. setting Adjusting range of 'Setting Air Temperature' in heating mode
Water heating set temp.
setting
DHW Set Temp.setting
Screed drying setting
Heater on temperature
Water supply off temp.
during cooling setting
Tank disinfection setting 1 Setting start/maintain time for pasteurisation
Tank disinfection setting 2 Setting pasteurisation temperature
Tank setting 1
Tank setting 2
Heater priority
DHW time setting
TH on/off Variable, heating
air setting
TH on/off Variable, heating
Water setting
Factory use only
Selection for setting temperature as air temperature or leaving
water temperature or air+leaving water temperature
Dry contact function is the function that can be used only when the
dry contact devices is separately purchased and installed.
When connecting the central control, set the central control
address of the unit.
Water pump test run
Adjusting range of 'Setting Leaving Water Temperature' in cooling
mode
Adjusting range of 'Setting Heating Flow Temperature' in heating
mode
Setting DHW set temperature
Setting for using Step 1 or 2 capacity of electric
Setting outdoor air temperature where half capacity of electric
heater starts operation.
Determine leaving water temperature when the unit is turned off.
This function is used for preventing condensation on the floor in
cooling mode
Setting start temperature for operation
Setting maintain temperature for operation
Determine electric heater and water heater on and off
Determine follow time duration : operation time of domestic hot
water tank heating, stop time of domestic hot water tank heating,
and delay time of DHW tank heater operating
Heating air temperature TH On / Off Type setting
Heating Water Outlet Temperature TH On / Off Type
INSTALLER SETTING
Description
89

Hide quick links: