Table 6- 4
Strain withstood / category (stand-
ard)
Vibration
(IEC 60068-2-6)
Vibration
(IEEE1613 Class V.S.2)
Shock
(IEC 60068-2-27)
SCALANCE X-300EEC
Compact Operating Instructions, 11/2015, A5E02630809-09
6.1 Construction, installation and environmental conditions
Mechanical stability
Test conditions
Frequency range 10 Hz to 150 Hz:
Transit frequency: 58 Hz to 60 Hz
•
Peak value of the displacement [mm] below the transit
•
frequency: 0.075
Peak value of the acceleration [g] above the transit fre-
•
quency: 1
Number of cycles per axis: 20
•
Frequency range 5 Hz to 150 Hz:
Transit frequency: 8.4 Hz
•
Peak value of the displacement [mm] below the transit
•
frequency: 3.5
Peak value of the acceleration [g] above the transit fre-
•
quency: 1
Number of cycles per axis: 10
•
Octaves / min: 1
•
Frequency range 2 Hz to 100 Hz:
Frequency range: 2 Hz to 100 Hz
•
Transit frequency: 13.2 Hz
•
Peak value of the displacement [mm] below the transit
•
frequency:1
Peak value of the acceleration [g] above the transit fre-
•
quency: 0.7
Number of cycles per
•
Velocity: <10 mm/s
•
Frequency: 1 to 150 Hz
•
Acceleration: 15 g
•
Duration of the pulse: 11 ms
•
Number of shocks per direction: 3
•
Technical data