Download Print this page

Cisco UCS 5100 Setup page 5

Fcoe connectivity
Hide thumbs Also See for UCS 5100:

Advertisement

Type exit to disconnect from nxos
Display of inventory will also show install of FC Modules into the switches
! exit from "nxos" mode to switch mode,
and making sure you are seeing the FC module
cae−sj−ca−B# show fabric−interconnect inventory expand
Switch A:
Switch Card:
Slot
Description
−−−−− −−−−−−−−−−−−−−−−−−−− −−−−−−−−−− −−−−−−−−−− −−−−−−−−−−−−−−− −−−−−−−−−−−
1 20x10GE/Supervisor
2 8x1/2/4G FC Module
2. Identify Fiber Channel components and Connectivity in Cisco UCS
Before you configure the fabric interconnect to support VSAN, you need to make sure that your FC uplink
expansion works and is visible from the fabric interconnect. Complete these steps:
1.
Log into UCS Manager GUI mode.
2.
In the Navigation pane, choose Equipment.
3.
Choose Fabric Interconnect > Fabric Interconnect #.
4.
Choose Uplink FC Ports.
Num Ports
State
20 Online
8 Online
PID
Serial (SN)
N10−S6100
JAF1242ASGK
N10−E0080
JAB123800NM

Advertisement

loading