4) upload the firmware using mt7681_uploader.exe, setting -f to specify the firmware
generated in the previous step, and -c to identify the new COM port, as shown below:
> mt7681_uploader.exe -f out\sta\MT7681_sta_header.bin -c COM7
5) successful upload of the firmware will result in the following being displayed:
Recovery Mode entered, Starting to upload...
138084/138084 bytes (100%) ... Update done! Bye
If this method fails, you can run the uploader using the Python script, as follows.
If you don't have Python installed, get it from
install.
Open cmd (using the Cygwin shell might not work ) and execute mt7681_uploader.py -f
out\sta\MT7681_sta_header.bin -c COM7
If the COM port is not shown in the PC's Device Manager and an error message states "FT230x
Basic UART driver not recognized", install the driver software from
Devices International
the Currently Supported VCP Drivers list. After installation, the COM port will be correctly
identified in Device Manager.
For more details on using mt7681_uploader.exe see section 3.2, 'Firmware uploader'.
2.4.3.2.
Uploading the firmware from Linux
To upload the firmware from a Linux computer:
1)
connect the LinkIt Connect 7681 development board to your computer using a USB cable,
as shown in Figure 17.
This document contains information that is proprietary to MediaTek Inc.
Unauthorized reproduction or disclosure of this information in whole or in part is strictly prohibited.
Limited. Download the executable version corresponding to your OS from
© 2015, 2016 MediaTek Inc.
MediaTek LinkIt™ Connect 7681 Developer's Guide
the downloads section at python.org
and
Future Technology
Page 19 of 65

Advertisement

Table of Contents
loading

Related Products for Mediatek Labs LinkIt Connect 7681

Table of Contents