Product Specifications - Panasonic CW-A90VE Service Manual

Room air conditioner
Table of Contents

Advertisement

CW-A90VE / CW-A120VE

1 Product Specifications

Model
Phase
Voltage
Frequency
Capacity
Running Current
Input Power
EER
W/W
BTU/hW
COP
W/W
BTU/hW
Starting Current
Noise Level
Power Noise Level
Fan Motor Output
Compressor Output
Moisture Removal
Air Circulation
Dimensions
Net Weight
Refrigerant (R-22)
Note: Specifications are subject to change without notice for further improvement.
CW-A90VE
Cooling
Single
220 - 230 V
50 Hz
2.67 - 2.68 kW
9,100 - 9,140 Btu/h
8,700 - 8,760 Btu/h
4.5 - 4.5 A
980 - 1,03K W
2.72 - 2.60 W/W
9.3 - 8.9
------
------
20 A
Indoor (High / Low):
Indoor (High / Low):
45 / 42 - 46 / 43 dB(A)
44 / 41 - 45 / 42 dB(A)
Outdoor (High / Low):
Outdoor (High / Low):
52 / 50 - 53 / 51 dB(A)
54 / 52 - 55 / 53 dB(A)
Indoor: 58 dB(A)
Outdoor: 64 dB(A)
Outdoor: 66 dB(A)
32/36 W
800 W
1.6 Ltr/h
3.4 Pint/h
3
8.5 m
/min.
3
300 Ft
/min.
Height: 14-25/32 inches (375 mm)
Width: 22-1/16 inches (560 mm)
Depth: 23-7/8 inches (606 mm)
35 kg
77 Ib
550 g
19.4 oz
Heating
2.55 - 2.57 kW
3.40 - 3.42 kW
11,600 - 11,700 Btu/h
3.8 - 3.9 A
6.5 - 6.9 A
820 - 880 W
1.36 - 1.48 kW
------
2.50 - 2.31 W/W
------
3.11 - 2.92 W/W
10.6 - 10.0
Indoor (High / Low):
48 / 45 - 49 / 46 dB(A)
Outdoor (High / Low):
56 / 53 - 57 / 54 dB(A)
Indoor: 56 dB(A)
Indoor: 62 dB(A)
Outdoor: 68 dB(A)
2
CW-A120VE
Cooling
Heating
Single
220 - 230 V
50 Hz
3.14 - 3.17 kW
10,700 - 10,800 Btu/h
5.3 - 5.7 A
1.10 - 1.21 kW
------
8.5 - 7.9
------
------
2.85 - 2.62 W/W
------
9.7 - 8.9
27 A
Indoor (High / Low):
48 / 45 - 49 / 46 dB(A)
Outdoor (High / Low):
58 / 55 - 59 / 56 dB(A)
Indoor: 61 dB(A)
Outdoor: 70 dB(A)
46/51 W
950 W
2.0 Ltr/h
4.2 Pint/h
3
9.5 m
/min.
3
340 Ft
/min.
Height: 14-25/32 inches (375 mm)
Width: 22-1/16 inches (560 mm)
Depth: 23-7/8 inches (606 mm)
39 kg
86 Ib
650 g
22.9 oz

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cw-a120ve