9 Operating Instructions

9.1.
CW-C170KR, CW-C200KR, & CW-C240KR (Cooling only).
9.1.1.
Parts Identification.
9.1.1.1.
Vertical Airflow Direction Vane.
9.1.1.2.
Ventilation Lever.
Airflow direction adjustment Up-and-Down.
• The vertical airflow direction vane is
controlled by positioning the vane to
discharge the air upwards, downwards
or straight out.
When the slide lever is in the:
• "OPEN" position, the ventilation door
opens to allow air, smoke or odours to be
expelled from the room.
• "CLOSE" position, the ventilation door is
closed and the air will be circulated inside
the room and conditioned.
9.1.1.3.
Recommended.
Use the air conditioner under the following conditions:
• Operating temperature range.
Indoor side
D.B.T.
Maximum
32° C
Temperature
Minimum
21° C
Temperature
D.B.T.: Dry Bulb Temperature
W.B.T.: Wet Bulb Temperature
Note: Humidity may exceed 90%.
− Continuous operation at over 90% high humidity may
create condensation and result in water drops on the
intake and outlet vanes.
12
Outdoor side
W.B.T.
D.B.T.
W.B.T.
23° C
43° C
26° C
15° C
21° C
15° C

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic CW-A170KR

  • Page 1: Operating Instructions

    CW-C170KR / CW-C200KR / CW-C240KR / CW-A170KR / CW-A200KR / CW-A240KR 9 Operating Instructions 9.1. CW-C170KR, CW-C200KR, & CW-C240KR (Cooling only). 9.1.1. Parts Identification. 9.1.1.1. Vertical Airflow Direction Vane. Airflow direction adjustment Up-and-Down. • The vertical airflow direction vane is...
  • Page 2: How To Operate

    “ON” for the vanes to swing from side to side until the desired flow direction is reached, then switch it to “OFF”. For continuous side-to-side air circulation, set the Air Swing Switch to “ON”. CW-C170KR / CW-C200KR / CW-C240KR / CW-A170KR / CW-A200KR / CW-A240KR Air Swing Switch Main Control knob Fig.
  • Page 3: Parts Identification

    CW-C170KR / CW-C200KR / CW-C240KR / CW-A170KR / CW-A200KR / CW-A240KR 9.2. CW-A170KR, CW-A200KR, & CW-A240KR (Cooling and Heating). 9.2.1. Parts Identification. 9.2.1.1. Vertical Airflow Direction Vane. Airflow direction adjustment Up-and-Down. • The vertical airflow direction vane is controlled by positioning the vane to discharge the air upwards, downwards or straight out.
  • Page 4 “OFF”. For continuous side-to-side air circulation, set the Air Swing Switch to “ON”. CW-C170KR / CW-C200KR / CW-C240KR / CW-A170KR / CW-A200KR / CW-A240KR Air Swing Switch Control Knob Main Control knob Fig.
  • Page 5: How To Install

    • Power supply point shall be the place where there is ease for the power disconnection in case of emergency. • Some installation locations may require installation of a short-circuit breaker. • Time delay fuse or circuit breaker rating is 16 Ampere for CW-C170KR/CW-A170KR/CW-C200KR/CW-A200KR and 20 Ampere for CW-C240KR/CW-A240KR.
  • Page 6: Installation Procedures

    Place Cabinet into the installation hole, then secure it with wood screws or nails. • Note: Tilt down for better drainage (max. 10 mm). CW-C170KR / CW-C200KR / CW-C240KR / CW-A170KR / CW-A200KR / CW-A240KR 10.3.4. Slide the Chassis back into the Cabinet.
  • Page 7: Removal Of The Front Grille

    CW-C170KR / CW-C200KR / CW-C240KR / CW-A170KR / CW-A200KR / CW-A240KR 10.3.7. Insert the Air Filter. 10.4. Removal of the Front Grille. 10.4.1. Remove the Front Intake Grille. • Raise the Front Intake Grille by approximately 90 . Slide it to the left to unhinge then pull outwards.
  • Page 8 4. Connect the drain hose to the outlet of Drain Pan bottom. 5. Slide the Chassis back into the Cabinet. Note: Drain hose or tubing can be purchased locally to satisfy your particular needs. CW-C170KR / CW-C200KR / CW-C240KR / CW-A170KR / CW-A200KR / CW-A240KR...

This manual is also suitable for:

Cw-c200krCw-c240kr

Table of Contents