Download Print this page

Makita HM1810 Manual page 19

Electric breaker
Hide thumbs Also See for HM1810:

Advertisement

W
iring diagram
[2] Wiring in Handle Sub Base
When Not Using Terminal Block
1) Before installing Switch, connect the lead wires with Insulated connectors as illustrated in Fig. 55.
Fig. 55
to Switch
boss
Insulated
connector
rib B
[Handle sub base viewed
from Handle side]
2) After installing Switch, connect the lead wires with Switch as illustrated in Fig. 56.
Fig. 56
Pin
rib B
Noise
suppressor
(if used)
rib D
How to Put Noise Suppressor in Place
If Noise suppressor is used, wrap it with sponge,
and put in the space between the rib A and the rib B
so that the surface A of Noise suppressor is parallel
to the bottom of Handle sub base as illustrated to right.
3) After finishing the wiring in Sub handle base, route the
following lead wires through the opening of Top cover
and Rear cover as illustrated in Fig. 57:
Lead wires of Lead unit
Relay wires (red)
opening of the pipe
boss
Insulated
connector
rib C
Connector of
Lead unit
Pin
Switch
Lead wires of Lead unit
Before routing, be sure to put through the pipe of
Handle sub base from Motor side as illustrated below.
Motor side
Route each wire between the inside wall of Handle
sub base and the rib B/ rib C.
Relay wires (white)
Route each wire between the boss and the inside wall
of Handle sub base.
Lead wires of Power supply cord
Route each wire between the inside wall of Handle
sub base and the rib B/ rib C.
Relay wires (red)
Before routing, be sure to
put through the pipe of
Handle sub base from
Motor side as illustrated
to right.
Relay wires (white)
Route each wire between the pin and the inside wall
of Handle sub base.
Lead wires of Noise suppressor
Be careful not to route over the ribs B and D.
Insulated connector
Fig. 57
Rear cover
P 19/ 20
Handle side
surface A
Noise suppressor
Sponge
Bottom of
Handle Sub Base
Handle sub cover
Top cover

Advertisement

loading