Editing the parameters ....................19 6.1.4 Entering the PIN code .....................21 6.1.5 Automatically quitting the menu ..................21 Basic menu ........................22 Extended functions (EF) ....................23 Info (INF) .........................24 Displaying the basic settings (slide show) ...............25 Function description ..................26 Overview ..........................26 www.schmalz.com...
Page 4
7.11.2 Zero-point adjustment of the sensor (calibration) ............36 Troubleshooting ....................37 List of error numbers .......................38 Maintenance and cleaning ................39 Cleaning the switch ......................39 Decommissioning ......................39 Accessories ....................... 40 Warranty ......................41 Conformity Declaration ..................42 4 | EN www.schmalz.com 30.30.01.00956/01...
This warning informs the user of a risk that could result in damage to property if it is not avoided. CAUTION Type and source of danger Consequence ► Remedial action General notes This symbol is used when important notes and information regarding the use of the machine/the system/the device are provided. Note/Information 30.30.01.00956/01 www.schmalz.com EN | 5...
Mandatory symbols Explanation of the mandatory symbols used in the operating instructions. Mandatory Description Mandatory Description symbols symbol Adhere to the operating instructions Wear eye protection Wear ear protectors Activate prior to maintenance or repair 6 | EN www.schmalz.com 30.30.01.00956/01...
► Only operate the switch using power supply units with protected extra-low voltage (PELV) ► The system must incorporate safe electrical cut-off of the power supply in betreiben compliance with EN60204 ► Do not connect or disconnect the plug connectors when voltage is applied 30.30.01.00956/01 www.schmalz.com EN | 7...
– including knowledge of applicable regulations – necessary to enable him or her to recognize possible dangers and implement the appropriate safety measures while performing tasks. Qualified personnel must observe the pertinent industry-specific rules and regulations." 8 | EN www.schmalz.com 30.30.01.00956/01...
Product Description General description The versions of the vacuum switch and pressure switch in the VSi series are referred to only as the switch below. The VSi-series switch can be operated in two operating modes. Users can choose between direct connection to discrete inputs (standard I/O = SIO mode) or connection through the communication line (IO link Class A).
Fluid connection Switching point 1 display, ORANGE or operating voltage display, GREEN Position of the NFC antenna behind the display Electrical connection M12-4 or M8-4 MODE button Display SET button Switching point 2 display, ORANGE 10 | EN www.schmalz.com 30.30.01.00956/01...
(also see separate data dictionary) Display (only VSi…D) 3-digit, 7-segment display with decimal point Vacuum 1 mbar Display resolution (only VSi…D) Pressure 10 mbar The power supply must correspond to the regulations in accordance with EN60204 (protected extra-low voltage). 30.30.01.00956/01 www.schmalz.com EN | 11...
Switch-on delay dS2, switch-off delay dr2 0 ms 0 ms 0 ms Transistor function Display unit mbar mbar mbar Eco mode Display alignment Standard Standard Standard IO link device locks, extended device locks Menu PIN code, NFC PIN code 12 | EN www.schmalz.com 30.30.01.00956/01...
Serious personal injury and/or damage to property ► The electrical connection must only be carried out by individuals who are able to assess the impact of signal changes on the overall machine / facility / system. 30.30.01.00956/01 www.schmalz.com EN | 13...
Page 14
Incorrect connection on IO-Link Class B Port. Poss. damage to the IO- Link Master or periphery ► When operating the IO-Link Class A switch with an IO- Link Master with Class B Port ensure compliant connection and isolation 14 | EN www.schmalz.com 30.30.01.00956/01...
OUT1 Black signal output 1 (SIO) when using a Schmalz connection line (see accessories) IO-Link commissioning When operating the switch in IO-link mode (digital communication), the supply voltage, Gnd and the C/Q communication cable must be directly connected with the corresponding connectors of an IO-Link master with Ports IO-Link Class A.
VSi VP8: 14 bit signed pressure in millibar (pressure positive, vacuum negative) A detailed description of all device parameters can be found in the data dictionary for the switch, which can be downloaded together with the IODD as a ZIP archive from www.schmalz.com. 16 | EN www.schmalz.com...
The switch functions as a passive NFC tag which can be read by a reader, e.g. smart phone or tablet. With the NFC applications by Schmalz, the information is displayed using a mobile website in the browser, therefore an app is not required. The smartphone must only have NFC activated and be connected to the internet.
23.6 11.6 - 1000 mbar With version V, the vacuum value, i.e. the vacuum compared to the ambient air pressure, is displayed as a positive; in version P10, it is displayed based on the pressure. 18 | EN www.schmalz.com 30.30.01.00956/01...
VP8 „InC“ (inconsistent) means that the value collides with the current setting of another parameter, e.g. rP1> SP1 To cancel the editing process, both buttons can be simultaneously pressed at any time. 30.30.01.00956/01 www.schmalz.com EN | 19...
Page 20
Write accesses from the IO-link and NFC interfaces have a higher priority than the operating menu, but generally last only a few seconds. However, if editing is attempted at the same time using the menu, this will be rejected with the display “LoC.” 20 | EN www.schmalz.com 30.30.01.00956/01...
The menu can be called up and used again afterward. If parameters are changed using one of the other interfaces, i.e. via the IO-link or NFC, the menu will also close. The instruction “dAt” will then appear for two seconds. 30.30.01.00956/01 www.schmalz.com EN | 21...
Switching point 2/lower window point 2 hy2/L-2 Hysteresis switching point 2 (window mode) or leakage limit 2 (CM mode) No / SP1 / SP2 Teach-in function No/yes Calibrate zero offset Submenu: Additional functions Submenu: Information Quitting the menu 22 | EN www.schmalz.com 30.30.01.00956/01...
Eco mode with display switch-off Lo: Eco mode with dimmed display Display alignment: Std (standard)/red (rotated) Pin code for the menu Transistor functions of both outputs: PnP/nPn No/yes Reset to factory settings Return to menu title 30.30.01.00956/01 www.schmalz.com EN | 23...
06.0 Part number: Display of next 3 numbers 2.00 Part number: Display of next 3 numbers Part number: Display of last 3 numbers Subsequent article number: 10.06.02.00589 Sno. 0.01 Serial number Return to menu title 24 | EN www.schmalz.com 30.30.01.00956/01...
The display cycle returns to the vacuum display after a complete cycle or can be canceled at any time by pressing any button. The switch is not a precise voltage meter, but the voltage displayed can still be used as a reference value and for comparative measurements. 30.30.01.00956/01 www.schmalz.com EN | 25...
Voltage measurement Minimum and maximum values HI/LO 7.10.1 Counters 7.10.2 Warnings and errors Exx/FFF/-FF System status 7.10.3 Condition monitoring 7.10.4 Reset to factory settings 7.11.1 Calibrating zero position 7.11.2 Resetting HI/LO 7.10.1 Resetting meters 7.10.2 26 | EN www.schmalz.com 30.30.01.00956/01...
(normally closed). A change in the switching point logic from NO to NC causes a logical inversion of the electrical switch outputs, the switching point bits in the IO-link process data and the orange LED display(s) on the switch. 30.30.01.00956/01 www.schmalz.com EN | 27...
Page 28
Values are considered “bigger” when they are further from zero and as “smaller” when they are closer to zero. The following diagram shows the switching point behavior using the two-point mode as an example: 28 | EN www.schmalz.com 30.30.01.00956/01...
(also see the data dictionary). If the resulting set of parameters are not valid in the new mode (e.g. hysteresis too big in window mode), it is not possible to switch the mode. 30.30.01.00956/01 www.schmalz.com EN | 29...
(e.g. a suction circuit with Schmalz SCP FS-RP-series ejectors). With such a system, the VSi can measure the vacuum leakage in millibars per second between two drainage cycles. The switching point is then activated when a leakage exceeds its maximum permissible setting, which can be configured.
The electrical characteristic of the switch outputs can be switched between PNP switching (“plus switching” or also 24V switching) and NPN switching (“zero switching” or also GND switching). Both switching outputs can always be set together, which does not affect the IO-link operation. 30.30.01.00956/01 www.schmalz.com EN | 31...
When a button is pressed or when an error message occurs, the display will be switched on again as normal. If you activate Eco mode using IO-Link, the display will immediately enter energy- saving mode. 32 | EN www.schmalz.com 30.30.01.00956/01...
SIO operating mode. It can only be canceled using IO-Link, not in the menu itself. The menu lock using the extended device access locks parameter has a higher priority than the menu PIN. That means that this lock also cannot be bypassed by entering a PIN. 30.30.01.00956/01 www.schmalz.com EN | 33...
Serial number and date code Version status of the hardware and firmware All character strings are available via the IO-link and NFC; only part numbers, serial numbers and the firmware revision can be retrieved from the menu. 34 | EN www.schmalz.com 30.30.01.00956/01...
This is also possible in the operating menu via the EF/rct menu item. The non-volatile storage of the counter statuses only occurs every 500 steps. That means that when the operating voltage is switched off, up to 499 steps of the counter are lost. 30.30.01.00956/01 www.schmalz.com EN | 35...
Using the “active error code” and “condition monitoring” parameter, as they are known by Schmalz vacuum ejectors. Using the “extended device status,” which transmits the entire display of the device status with classification of the severity level of errors and warnings.
Set thresholds in such a way that Threshold values SPx and rPx for there is a clear differentiation leakage measurement set too high. between the neutral and suction system statuses. 30.30.01.00956/01 www.schmalz.com EN | 37...
VSi measurement value (FFF/-FF), version Teach-in error Teach-in for leakage mode was carried out Ensure that the measurement value with existing pressure is in the vacuum range in V8 leakage mode 38 | EN www.schmalz.com 30.30.01.00956/01...
9.2 Decommissioning After being replaced or after final decommissioning, the switch is to be disposed of in accordance with country-specific regulations. CAUTION Incorrect disposal of the switch Environmental damage ► Disposal according to country-specific regulations 30.30.01.00956/01 www.schmalz.com EN | 39...
This system is guaranteed in accordance with our general terms of trade and delivery. The same applies to spare parts, provided that these are original parts supplied by us. We are not liable for any damage resulting from the use of non-original spare parts or accessories. 30.30.01.00956/01 www.schmalz.com EN | 41...
CONFORMITY DECLARATION 12 Conformity Declaration 42 | EN www.schmalz.com 30.30.01.00956/01...
Page 43
In den kurzen Videobeiträgen erklären wir einfach und verständlich die umfang- reichen Funktionen, die in unseren Produkten stecken. Einfach reinschauen, es lohnt sich! www.schmalz.com/gewusst-wie Weitere Serviceleistungen von Beratung bis Schulung finden Sie unter www.schmalz.com/services J. Schmalz GmbH Johannes-Schmalz-Str. 1 D-72293 Glatten Tel. +49 (0)7443 2403-0 Fax +49 (0)7443 2403-259 schmalz@schmalz.de 30.30.01.00956/01 | 03.2019...