Download Print this page

E-matic PMSCF Installation And Operating Instructions

Ceiling pir sensor

Advertisement

Quick Links

INSTALLATION AND OPERATING INSTRUCTIONS FOR CEILING PIR SENSOR
Thank you for choosing PMSCF PIR sensor. This sensor is suitable for INDOOR use only. Please read these instruction before
installation and keep for future reference.
IMPORTANT: Installation must be performed by a skilled/competent person who is familiar with the appropriate standards and
technical requirements of the appliance and its proper installation.
Never modify the unit, there are no user serviceable parts inside. Not suitable for use with dimmer switches. Install in accordance
with IEC Wiring Regulations.
■ POSITIONING THE UNIT
When selecting the mounting position, please take the following points into account:
1.
The sensor is designed for optimum performance to be mounted on the ceiling (see Figure 2)
2.
Ensure that the sensor cannot pick up or is close to heat sources such as heater or heat extraction units, which may cause
false triggering.
3.
If you set the Lux control level to night ( ), ensure that the sensor cannot detect bright light as that the unit will not work.
4.
Do not fit the sensor near strong electromagnetic fields as false activations may occur.
■ FITTING THE UNIT (See Figure 1)
Before any electrical work, ensure mains supply cables is isolated by switching off and removing the relevant fuse.
1. Drill a circle hole of around 2.5-inch (63.5mm) diameter in the ceiling where you are to mount the sensor
2. Remove the terminal cover ① and unscrew the cable clamp ② (see Figure 1)
3. Connect the main supply cable to the corresponding terminals
Brown (Main
power Activel)
Blue (Main
power Neutral)
Blue(Load)
Black(Load)
MODEL: PMSCF
Figure 1
1
2
out
in
Max 4.5M
L N L
Max 4M
Detection Area Figure 2
Ceiling
360°
Max 4.5M
Radius
Ceiling
360°
Max 4M
Radius
PMSCF Instructions Rev02

Advertisement

loading

Summary of Contents for E-matic PMSCF

  • Page 1 MODEL: PMSCF INSTALLATION AND OPERATING INSTRUCTIONS FOR CEILING PIR SENSOR Thank you for choosing PMSCF PIR sensor. This sensor is suitable for INDOOR use only. Please read these instruction before installation and keep for future reference. IMPORTANT: Installation must be performed by a skilled/competent person who is familiar with the appropriate standards and technical requirements of the appliance and its proper installation.
  • Page 2 “AUTO MODE”. While sensor is in the AUTO MODE, you can then carry out a Walk-Test by placing the LUX control to day position ( ) and the TIME control to minimum (-). Once the PMSCF sensor receives a valid trigger signal (such as movement of a person) within its detection area, the lamp(s) (load) will be turned on for the pre-set period of time.
  • Page 3 Due to our policy of continuous improvement we reserve the right to change specification without prior notice. Errors and omissions excepted. These instructions have been carefully checked prior to publication. However, no responsibility can be accepted by E-Matic for any misinterpretation of these instructions. E-Matic Energy Management Solutions...