Communication Using Function Blocks
Parameters of the RES_RECV FB
The following table lists the parameters of the RES_RECV FB.
Table 6-4
Parameters of the RES_RECV FB
Name
Type
REQ
INPUT
R
INPUT
LADDR
INPUT
1
DONE
OUTPUT
1
ERROR
OUTPUT
1
STATUS
OUTPUT
1
The parameter is available until the next call of the FB.
6-16
Data Type
Comment
BOOL
Initiates job with positive
edge
BOOL
Aborts job
INT
Basic address of the
CP 440
BOOL
Job completed without
errors
BOOL
Job completed with errors
WORD
Specification of the error
Point-to-point connection CP 440 Installation and Parameter Assignment
Permitted Values,
Comment
Current job is aborted. Sending
is disabled.
The basic address is taken from
STEP 7.
STATUS parameter == 16#00;
STATUS parameter contains
error information
If ERROR == 1, STATUS
parameter contains error
information