Routine Maintenance; Troubleshooting - Accurex XRRS Installation, Operation And Maintenance Manual

Fire ready hood
Table of Contents

Advertisement

Routine Maintenance

Monthly
Cleaning
Suppression Nozzles
Temperature Sensors
Extinguisher Tank
To clean hood, wipe grease from exposed metal
surfaces on the hood interior using a clean, dry cloth.
Stainless steel hood exterior surfaces should be cleaned
with a mild detergent then polished with a high grade
stainless steel polish to preserve the original luster.
Routinely remove metal mesh grease filter from the
hood and clean using hot water and mild detergent.

Troubleshooting

Problem: Fan won't turn on
Fan not turned on by user interface
External inline fan not connected
Fan by others not connected
Fan by others not wired correctly
Problem: Hood is spilling smoke
Fan is not on
Hood not centered above range
Fan is not calibrated
Appliance is not correct size/type for fire
ready hood
Problem: Range doesn't work
Range not unlocked by user interface
Electric range breaker tripped/off
Gas range breaker feeding disconnect
assembly box tripped/off
Hood temperature exceeding high
temperature setpoint
Fire suppression control board fault
Electric/gas disconnect assembly box not
wired
No gas flowing to gas range
Every
Annually
10 Years
Yes
Yes
Inspect
Inspect
Inspect
Inspect
Inspect
Recertify
Replace
Press fan button on user interface
Connect external inline fan to plug and play cable
Connect fan by other to quick connector
Make sure 0-10VDC and 115VAC wires are not reversed. Confirm signals using
voltage meter
Turn fan on by pressing fan button on user interface
Center range below hood
See "Fan Calibration", page 14
Appliance must be residential range type and either 30 or 36 inches long (for 30
or 36 inch long hood configurations).
Press range / lock icon (and enter password) to unlock range
Reset breaker
Reset breaker
Decrease cooking/shut off range to allow heat to subside in hood capture tank
Correct control board fault and reset board (see Fire System Diagnostics, page
21)
Confirm both 6 ft. plug and play control cables are connected between hood and
disconnect assembly box
Confirm gas valve is receiving 24VAC voltage between black and white wires
NOTE
Never use abrasive cleaners or chemicals on hood
surfaces. Never use chlorine based cleaners or iron
wool pads to clean the hood. They may scratch or
mar the material, allowing pitting and rust to form.
Always rub with the grain of the stainless when
cleaning.
Replace hood lights, sensors, and other components as
necessary.
On front recirculation models, replace charcoal filter
routinely (as needed) to help catch cooking odor
molecules when recirculating air back into the space.
Fire Ready Hood
23

Advertisement

Table of Contents
loading

Table of Contents