Accessories

Remote Mounted User Interface (if applicable)
Skip these steps if the user interface is factory mounted
on the hood.
1. Recess mount the user interface box near hood
(cable provided is 8
1
feet in length).
2
2. Follow electrical installation instructions for remote
mounted user interface on pages 11 and
NOTE
To comply with ADA standards, interface (if mounted
on an unobstructed wall) must be a max of 48 inches
off of the finished floor.
5.97
3.45
WALL HOLE
3.13
CUT-OUT SIZE
Dimensions shown are in inches.
Finished Top (if applicable)
A finished top can be included with all integral fan
configurations when there are no cabinets covering the
top of the hood. If provided with a finished top, the top
piece will be attached to the hood when shipped.
1. Remove the finished top piece after mounting the
hood. Once the hood full installed and armed, fasten
the finished top piece to the top of the hood using
fasteners provided.
12.
2.49
3.13
3.45
5.66
Ceiling Enclosures (if applicable)
Ceiling enclosures may be included with the system
to close off the top of the hood when configured for
external fan – top discharge, to hide ductwork if no
kitchen cabinets enclose the top of the hood.
1. Remove screws that attach enclosure mounts to
enclosure panels.
2. Fasten enclosure through pre-drilled holes to wall
using appropriate field provided fasteners.
3. Attach enclosure panels to enclosure mounts using
the screws removed in step 1.
Enclosure Mount
Enclosure Fasteners
Enclosure Panels
Dimensions shown are in inches.
Wall Cap (if applicable)
A wall cap with built in birdscreen and damper may
be provided for internal fan – rear discharge hood
configurations that exit the building through an external
wall.
1. Once wall mounting bracket is installed, cut hole in
wall and install 5 x 12 inch duct to line up with hood
opening.
2. On outside wall, affix wall cap to cover duct opening.
Seal all joints to prevent air and water leaks.
Dimensions
shown are
in inches.
12.25
5.5
8.75
NOTES:
1. Steel construction with black enamel finish
2. For outside wall applications
3. Built-in birdscreen and damper
4. To use with 5 x 12 inch duct (provided by others) with
internal fan - rear discharge hood configuration
Enclosure
Height
30 or 36
12
15.25
6.75
15.0
13.5
Fire Ready Hood
9