Parameter
Return parameter <NRf>
Example
Query Example
Display Commands
DISPlay:MENU[:NAME]
Description
Syntax
Query Sytax
Parameter/
Return parameter
<NRf> 0% ~ 105% of the rated output
<voltage>
voltage.
<NRf> 0% ~ 105% of the rated output
<current>
current.
0 volts/0 amps
MIN
Maxium value for the present range.
MAX
Returns the voltage and current.
APPL 5.05,1.1
Sets the voltage and current to 5.05V and 1.1A.
APPL?
+5.050, +1.100
Returns voltage (5.05V) and current (1.1A) setting.
DISPlay:MENU[:NAME] ................................................... 43
DISPlay[:WINDow]:TEXT:CLEar .................................... 44
DISPlay[:WINDow]:TEXT[:DATA] ................................. 44
DISPlay:BLINk ..................................................................... 45
The DISPlay MENU command selects a screen
menu or queries the current screen menu.
DISPlay:MENU[:NAME] <NR1>
DISPlay:MENU[:NAME]?
Description
<NR1>
Measurement-Voltage / Measurement-
0
Current
Measurement-Voltage / Measurement-Power
1
Measurement-Power / Measurement-Current
2
Set Menu
3
OVP / OCP Menu
4
Not Used.
5~99
F-00~99 Menu.
100~199
REMOTE CONTROL
Set
Query
43