Technical Data - ABB MNS R System Manual

Main distribution switchgear
Hide thumbs Also See for MNS R:
Table of Contents

Advertisement

Technical data

Reference Standards
Test certification
Electrical Data
Rated voltages
Rated currents
Arc-proof
Values
Mechanical
Dimensions
characteristics
Surface protection
Degrees of protection
IEC 529, EN 60529 Standards
Construction form
Normal conditions
Extra options
Paint
Busbar system
Forms of segregation
ABB SACE
ABB SACE L.V. MNS R switchgear
Standards conformed to
Test certificates
Rated insulation voltage
Rated service voltage Ue
Rated frequency
Impulse withstand voltage
Main busbars:
Rated current
Rated peak withstand current
Rated short-time withstand current (1s)
Distribution busbars:
Rated current
Rated peak withstand current
Rated short-time withstand current (1s)
100 kA, 0,3 s. at
415 V
Height
Widht
Depth
Module base (height)
Frame
Internal divisions
Transversal section
Housing (doors and external curtain panels)
With door open
With door closed
3a, 3b, 4b
Installation
Ambient temperature
Relative humidity
Max. altitude
External protection
Main and branch busbars
According BS 60439-1
CEI EN 60439-1, IEC 439-1
ABB SACE, ACAE LOVAG and SINAL
up to 1000 V AC 1500 V DC
up to 690 V AC 750 V DC
50 - 60 Hz
12 kV
up to 6300 A
up to 220 kA
up to100 kA
630÷4000 A
220 kA
100 kA
IEC 61641 (on request)
2200 mm
300, 400, 600, 800, 1000, 1200 mm
1025, 1200, 1400, 1600 mm
E = 25 mm DIN 43660
Al-Zn galvanisation
Galvanised sheet UNI EN 10130
Electrolytic galvanisation UNI ISO 4520
Painting RAL 7035
IP20
IP30 standard, up to IP 54
internal for service
-5 °C; +40 °C
max. 50% at 40 °C
2000 m
colour on request
sheathed busbars, treated busbars (Ag/Sn)
4b type 1÷7
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents