Lift truck on-board check weighing, utilization & impact management, utilization factor default setting is 30 impact default low setting is 4.0 g impact default high setting is 8.0 g programmable keypad operator id's. valid operator id value is up to 3 di (20 pages)
General Installation Guide This ED3-EP and ED4-EP SkidWeigh Plus V1.25 Series installation & calibration guide describes how to install, calibrate, test and use your on-board check weighing unit. Following the instructions in the ADMINISTRATION MENU guide will enable you to get the system set up and weighing calibration function operating quickly. In the event that you require additional assistance, please contact customer support via e-mail at support@skidweigh.com , visit...
Page 3
Operational principal The ED3-EP and ED4-EP SkidWeigh Plus operational principal is based on the hydraulic pressure transducer mounted in the vehicle lifting hydraulic circuit and lift accurate technology. The load should be placed all the way in towards the load back guard. With the load lowered to the ground the LCD display will show time and date which is a starting point to initiate a load weight procedure.
Electrical connections All SkidWeigh systems operate from 12 to 55 VDC. - Orange Wire (+) Ignition switch On position - Brown Wire (-) Battery negative - Red Wire, connect to RED wire of the pressure transducer cable - Black Wire, connect to BLACK wire of the pressure transducer cable - White Wire, connect to WHITE wire of the pressure transducer cable Two Black wires are connected to internal relay, dry contacts located in ED3/ED4-EP digital indicator.
Page 5
If the forks are lifted above the ground LCD digital display will show “PLEASE WAIT” and within few seconds display will show “some” load weight . (Example: 455, not calibrated load weight at this stage) LCD Display PLEASE WEIGHT WEIGHT = 455 If the above test is valid than the system electrical connections are done right.
Page 6
Impact Monitoring LCD Display Special Functions Button Bluetooth Icon Mounting Bracket With Anti Vibration Mounts Power Switch Keypad Toggle Arrows Keys in set up menu “Enter key” ↵ Print key or /and USB recording, wireless data SEND FUNCTION MODE KEY ADMINISTRATIVE MENU (Password protected) OPERATOR MENU...
Administrative Menu The administration menu allows the installation technician to calibrate system weighing function ( SET CALIBRATION 1) and for the end user to manage data, set vehicle ID#, time, utilization factor, impacts, etc., information available depending on the purchased hardware and configurations.
LCD Display MENU Password = ___ LCD Display <> KEY to SCROLL F KEY TO EXIT Date / Time Set Up LCD Display SET CLOCK ENTER TO SELECT LCD Display SET CLOCK AUTO _ Use left ◀ and right ▶ arrow key (bottom left side of the keypad) to change from AUTO to MANUAL date/ time set up.
Page 9
LCD Display Aug 28, 2010 12:20:23 “Enter key” ↵ Press to confirm the setting. The cursor will automatically move to the next item to be changed ( Month, Day, Year, Hours, Minutes, Seconds). On the last correction, seconds item press “Enter key” ↵ to confirm new date / time set up.
Page 10
Lift Accurate Technology Automatic lift motor travel de-activation methods during the load weighing cycle Two BLACK wires are connected to the internal relay, dry contacts located in the ED3/ED4-EP digital indicator. This internal relay is controlled by the microprocessor and activate only during the load weigh- ing cycle.
Page 11
Method B. (Some older electric pallet trucks with solenoid coil wiring interface) Use two Black wires and splice them in series with one of the lift solenoid coil wires acti- vating the lift motor. Disconnect one of the original solenoid coil wire ( From either positive or negative terminal of the solenoid coil ) and splice two BLACK wires in series to disconnected wire and the so- lenoid terminal.
Page 12
Once the load weight is shown on the LCD display internal relay will be de-activated and the lift motion control will be enabled. (With vehicle stationary and during the lifting cycle diagnostic display on some vehicles might show “ No power to lift motor”...
Page 13
Weighing scale function calibration The ED3/ED4-EP SkidWeigh Plus calibration is automatic and is done by lifting empty and loaded forks with known load weight. MAKE SURE THAT YOU HAVE A KNOWN LOAD WEIGHT AND KEEP IT NEARBY TO COMPLETE THE CALIBRATION.
Page 14
System zero load value will be calibrated. After few seconds the LCD display will show LCD Display CALIBRATION 1 LOWER FORKS Lower the empty forks to the ground. The LCD display prompt you to input known calibration load weight. LCD Display CALIBRATION 1 WEIGHT = ❏...
Page 15
After few seconds the calibrated load weight value of 2000 will be stored in the system memory and LCD display will prompt you to lower “LOWER FORKS”. System weighing function is completed. LCD Display CALIBRATION 1 CONFIGURATED As soon the loaded forks are lowered to the ground LCD will show data / time. System is ready to be used! LCD Display AUG 28, 2010...
Saving recorded data to USB memory stick The ED3/ED4-EP SkidWeigh Plus system will allow you to download all recorded data to the memory stick. Follow instructions shown on the LCD display This function is located in Administrative Menu. LCD Display <>...
Page 17
Lift Truck Operator Guide Power Switch Print / Send “Enter key” ↵ Operator Menu F0 Turn on power to the system - Insert forks into the pallet or under the product to be weighed - Lower the loaded forks to the ground. LCD display must show date / time - Activate lift motor control switch and hold it until lifting cylinder is automatically stopped - LCD display will show “PLEASE WAIT”...
“P” key Functions - Systems with USB port by pressing “P” key load weight data will be recorded and can be downloaded to the memory stick at any time - Systems utilizing RF wireless module by pressing “P” key load weight will be send to the base station Accumulative Load Weight Total - With LCD display showing load weight by pressing “Enter key”...
Need help?
Do you have a question about the ED3-EP SkidWeigh Plus Series and is the answer not in the manual?