Integrated Visual Data Technology Inc. ED3 SkidWeigh Plus Series Installation & Calibration Manual

Keypad operator vehicle access, lift truck on-board check weighing system,impact detection with keypad authorized operator access control
Hide thumbs Also See for ED3 SkidWeigh Plus Series:

Advertisement

Quick Links

!
Installation & Calibration Manual
ED3/ED4 SkidWeigh Plus
Lift Truck On-board Check Weighing System,Impact Detection
with Keypad Authorized Operator Access Control
* Weighing Scale
* Vehicle Impact Detection
* Operator Access Control
Integrated Visual Data Technology Inc. 3439 Whilabout Terrace, Oakville, Ontario, Canada L6L 0A7
(
Keypad Operator Vehicle Access Series)
(Keypad ID# input)
ED3/ED4 Keypad Access V1.30
www.skidweigh.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ED3 SkidWeigh Plus Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Integrated Visual Data Technology Inc. ED3 SkidWeigh Plus Series

  • Page 1 Installation & Calibration Manual ED3/ED4 SkidWeigh Plus Keypad Operator Vehicle Access Series) Lift Truck On-board Check Weighing System,Impact Detection with Keypad Authorized Operator Access Control * Weighing Scale * Vehicle Impact Detection * Operator Access Control (Keypad ID# input) ED3/ED4 Keypad Access V1.30 Integrated Visual Data Technology Inc.
  • Page 2: Electromagnetic Compatibility

    General Installation Guide This ED3 / ED4 SkidWeigh Plus V1.30 Series installation & calibration guide describes how to install, calibrate, test and use your on-board check weighing unit. Following the instructions in the ADMINISTRATION MENU guide will enable you to get the system time set up and weighing calibration function operating quickly. In the event that you require additional assistance, please contact customer support via e-mail at support@skidweigh.com , visit...
  • Page 3: Pressure Transducer Installation

    Load weight operational principal The ED3 / ED4 SkidWeigh Plus series load weight operational principal is based on the hydraulic pressure transducer mounted in the vehicle lifting hydraulic circuit that will automatically activate the “weighing cycle / specific algorithm ” every time a skid load is lifted just above the ground. The increase in pressure is converted in an electronic signal at the sample rate of 16000 readings which is converted into a load weight reading.
  • Page 4: Compact Size

    Compact size All of the SkidWeigh systems are compact, housing dimension of only 120 x 80 x 55 mm is ideal for the installations to material handling vehicles of all kinds. Electrical connections All SkidWeigh RFID equipped systems operate from 12 to 55 VDC. Digital indicator with eight wires single cable - Orange Wire (+) Ignition switch On position - Brown Wire (-) Battery negative...
  • Page 5 Keypad SCROLL KEYS “Enter key” ↵ F 9 Administrative Menu F 0 Operator Menu Print and save to USB port All SkidWeigh systems are internally short circuit protected with resettable fuse. There is no need to install external inline fuse in orange wire that is connected to the ignition switch. Note: ED3 ED4 Keypad Operator Access Control SkidWeigh Plus system is utilizing keypad as the input for the operator access control.
  • Page 6: Set Clock

    Administration Menu Instructions (Time/Date, Vehicle ID#, Impacts Setup, OSHA Safety, USB Data Upload, Weight Scale Function Calibration) To enter into the Administration Menu with LCD display showing “ENTER ID NUMBER” input factory default ID# 111. The LCD display will show date/time. Press F key and than number 9 and input password 521. Use left and right arrow keys to scroll and follow the LCD instructions.
  • Page 7 LCD Display Aug 28, 2010 12:20:23 “Enter key” ↵ Press to confirm the setting. The cursor will automatically move to the next item to be changed ( Month, Day, Year, Hours, Minutes, Seconds). On the last correction, seconds item press “Enter key” ↵ to confirm new date / time set up.
  • Page 8: Saving To Usb

    USB port USB Port Protective Cover Saving data to USB memory stick - Insert memory stick into USB port With LCD display showing date /time press F key and than number 9 and input password 521. Follow instructions shown on the LCD display. LCD Display <>...
  • Page 9 Weighing scale function calibration The ED3 /ED4 Keypad Operator Access Control SkidWeigh Plus system calibration is automatic and is done by lifting empty and loaded forks (or any other attachment such as paper clamp) just above the ground. MAKE SURE THAT YOU HAVE A KNOWN LOAD WEIGHT AND KEEP IT NEARBY TO COMPLETE THE CALIBRATION.
  • Page 10 After few seconds the LCD display will show LCD Display CALIBRATION 1 LOWER FORKS At this point you must lower the empty forks to the ground. The LCD display prompt you to input known calibration load weight. LCD Display CALIBRATION 1 WEIGHT = ❏...
  • Page 11: Overload Warning Function

    LCD Display CALIBRATION 1 LOWER FORKS LCD Display CALIBRATION 1 CONFIGURATED As soon the loaded forks are lowered to the ground LCD will show data / time. System is ready to be used! LCD Display AUG 28, 2010 12:25:23 Overload warning function (Optional Function As soon as the loaded forks are lowered to the ground during the weighing function calibration the LCD will prompt you to input the overload value for your vehicle application.
  • Page 12 Supervisor Menu Instructions Set Impacts Low impacts, default value set to 4G High impacts , default value set to 8G Audible buzzer warning for low and high impacts Audible buzzer warning time from 1 to 60 seconds Continuous audible buzzer warning To enter into the Supervisor Menu, press F and than number 9 key and input password 521.
  • Page 13 LCD Display 8.0 G _ LCD Display ENTER HI IMPACT CONTINUOUS ? Y LCD Display ENTER HI IMPACT CONTINUOUS ? Y LCD Display IMPACT CONFIGURATED Start point to program valid operator ID#’s - With power turned on to the system the LCD display will indicate to “ENTER ID NUMBER” LCD Display ENTER ID NUMBER ID =...
  • Page 14 LCD Display ENTER VALID IDS ID 2 = 222 - LCD display will advance and prompt you to input third valid operator ID# and so on. LCD Display ENTER VALID IDS ID 3 = 333 * Above example showing operators ID# 111, 222 and 333. On the last valid operator ID number that you have inputed into the system you must press “Enter key”...

This manual is also suitable for: