Install the heatsink.
10.
IMPORTANT:
system board.
Install all components removed from the failed system board.
11.
Install the hard drive cage/bezel assembly
12.
Install the access panel
13.
Restore the serial label pull tab to the original position.
14.
Install the server blade.
15.
After you replace the system board, you must re-enter the server serial number and the product ID.
During the server startup sequence, press the F9 key to access RBSU.
1.
Select the System Options menu.
2.
Select Serial Number. The following warning is displayed:
3.
WARNING! WARNING! WARNING! The serial number is loaded into the system
during the manufacturing process and should NOT be modified. This option
should only be used by qualified service personnel. This value should
always match the serial number sticker located on the chassis.
Press the Enter key to clear the warning.
4.
Enter the serial number and press the Enter key.
5.
Select Product ID.
6.
Enter the product ID and press the Enter key.
7.
Press the Esc key to close the menu.
8.
Press the Esc key to exit RBSU.
9.
Press the F10 key to confirm exiting RBSU. The server will automatically reboot.
10.
Install all components with the same configuration that was used on the failed
("Hard drive cage/bezel
("Access
panel" on page 24).
assembly" on page 27).
Removal and replacement procedures 44