Con; Txd; Quit - EMS 7940 IRIS+ Installation And Programming Instructions

High powered uhf contact operated transmitter
Table of Contents

Advertisement

EMS 7000 IRIS +

7. CON

7.1 Each of the transmitters inputs can be programmed to operate via a normally open
or normally closed configuration. Note: Inputs 1, 2, 7 and 8 are only used on this
device. Input 1 activating an alarm transmission, input 2 a local transmission, input
7 a low battery transmission and input 8 a tamper transmission. The default setting
for all of the inputs is to normally open. Note: As the tamper input is pre-wired at
the factory this setting will be changed to normally closed.
changing, from the command menu type con and press the enter key.
The display will then show:
Contact 1 is N/O
Change Y/N
To change to N/C press Y and then enter. The display will then change to show the
next contact input:
Contact 2 is N/O
Change Y/N
If a change is not required press N or Enter. The display will then change to show
the next input.
This continues until all 8 contacts are looked at. On answering Y/N to contact 8 the
display will change to show the command menu. To check settings type con to re-
enter menu.

8. TXD

8.1 The txd function when entered causes the transmitter to transmit call in data
approximately once every second. This shows the transmitter is transmitting valid
data. To enter this function, type txd from the command menu and press the enter
key. The display will then show,
CALL IN....
Transmitting Burst...

9. QUIT

9.1 To update any information changed and exit the programming mode, quit must be
typed followed by pressing the enter key. The program mode is then exited. The
display will then show any transmissions from the transmitter in the following
format:
Transmitting Burst...
7940 ENGINEERS GUIDE v2.2 – 13/04/10