Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
EMS Manuals
Receiver
7000 Iris+
Operating instructions manual
EMS 7000 Iris+ Operating Instructions Manual
Uhf remote receiver
Hide thumbs
Also See for 7000 Iris+
:
Installation and programming instructions
(22 pages)
1
Table Of Contents
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
page
of
16
Go
/
16
Contents
Table of Contents
Bookmarks
Table of Contents
Table of Contents
Introduction
Wiring Details
Tools & Test Equipment
Remote Receiver Positioning
Electrical Installation
Software con Guration
Iris+ Main Menu
Main Iris+ Receiver Software con Guration
Testing the System
Measuring the Background Level
On-Site Range Testing
Site Testing with a Pager
Site Testing (Single Person)
Site Testing (Two Person)
Commissioning & Programming
Wiring
Advertisement
Quick Links
Download this manual
See also:
Installation and Programming Instructions
7258 UHF Remote Receiver
Operating Instructions
©2018 EMS Ltd. All rights reserved.
Page 1 of 16
MK108 Iss4 27/07/2018 AJM
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Related Manuals for EMS 7000 Iris+
Transmitter EMS 7940 IRIS+ Installation And Programming Instructions
High powered uhf contact operated transmitter (22 pages)
Receiver EMS 53-5414 Installation And Programming Instructions
Vhf & uhf remote receivers (16 pages)
Summary of Contents for EMS 7000 Iris+
Page 1
7258 UHF Remote Receiver Operating Instructions ©2018 EMS Ltd. All rights reserved. Page 1 of 16 MK108 Iss4 27/07/2018 AJM...
Page 2: Table Of Contents
Testing the System Measuring the Background Level On-site Range Testing Site Testing with a Pager Site Testing (Single Person) Site Testing (Two Person) Commissioning & Programming Wiring ©2018 EMS Ltd. All rights reserved. Page 2 of 16 MK108 Iss4 27/07/2018 AJM...
Page 3: Introduction
The maximum overall cable run for the RS485 Bus is 1000 metres. A block diagram showing examples of correct / incorrect Remote Receiver wiring is shown overleaf in Figure 1. ©2018 EMS Ltd. All rights reserved. Page 3 of 16 MK108 Iss4 27/07/2018 AJM...
Page 4
Iris+ Remote Receivers No End Of Line Required Line Iris+ Remote Receivers Remote Receiver Iris+ Remote Remote Receivers Receivers Iris+ Remote Remote Receiver Receivers Figure 1 ©2018 EMS Ltd. All rights reserved. Page 4 of 16 MK108 Iss4 27/07/2018 AJM...
Page 5: Tools & Test Equipment
Iris+ and Remote Receivers door assembly. The jumper is located top centre of the PCB. The RS485 port is used as the Remote Receiver Bus. The maximum overall cable run is 1000 metres. ©2018 EMS Ltd. All rights reserved. Page 5 of 16 MK108 Iss4 27/07/2018 AJM...
Page 6: Software Con Guration
Direct Inputs Time Control Txer Grouping Figure 2 The Main Menu can be scrolled through using the & keys on the front keypad of the Iris+ Receiver. ©2018 EMS Ltd. All rights reserved. Page 6 of 16 MK108 Iss4 27/07/2018 AJM...
Page 7: Main Iris+ Receiver Software Con Guration
Press the key, to select. The following screen prompt will be displayed: Master Port=0, 0= O , 1=RS485, 2=Pager 232 > _ =Done =Del 14:29 Figure 4 ©2018 EMS Ltd. All rights reserved. Page 7 of 16 MK108 Iss4 27/07/2018 AJM...
Page 8
A time out is where Comms between Timeouts that have occurred and the Iris+ Receiver and the Remote dd is the last device to time out. Receiver is lost momentarily. ©2018 EMS Ltd. All rights reserved. Page 8 of 16 MK108 Iss4 27/07/2018 AJM...
Page 9: Testing The System
A typical carrier display is shown below. See the Iris+ Instructions for further information if required. Monitor Carrier Level = 26 Highest = 27 14:30 Figure 7 ©2018 EMS Ltd. All rights reserved. Page 9 of 16 MK108 Iss4 27/07/2018 AJM...
Page 10: On-Site Range Testing
The pager receiver should now receive a signal. An example of a received test message is shown in the following display: TEST 192 Local: Hand Push 001 ©2018 EMS Ltd. All rights reserved. Page 10 of 16 MK108 Iss4 27/07/2018 AJM...
Page 11: Site Testing (Single Person)
Continue the testing until the signal strength readings have been successfully taken from all points of required site coverage. Return the Iris+ Control key to the ‘Clear’ position on completion of tests. ©2018 EMS Ltd. All rights reserved. Page 11 of 16 MK108 Iss4 27/07/2018 AJM...
Page 12: Site Testing (Two Person)
RG213 low loss co-axial cable. Move the nearest receiver to a more favourable position, away from the likely source of interference. ©2018 EMS Ltd. All rights reserved. Page 12 of 16 MK108 Iss4 27/07/2018 AJM...
Page 13: Commissioning & Programming
Should it be necessary to alter the setup, consult the programming guide for details on how to reprogram the Iris+ Receiver. ©2018 EMS Ltd. All rights reserved. Page 13 of 16 MK108 Iss4 27/07/2018 AJM...
Page 14: Wiring
To Next Remote Receiver (IN) Remote Receiver Back OUT- OUT+ TAMPER TAMPER Iris+ Receiver Back box OUT- OUT+ TAMPER TAMPER HARDWIRED INPUTS REMOTE BUZZER 12Vdc Input 750mA MIN ©2018 EMS Ltd. All rights reserved. Page 14 of 16 MK108 Iss4 27/07/2018 AJM...
Page 15
©2018 EMS Ltd. All rights reserved. Page 15 of 16 MK108 Iss4 27/07/2018 AJM...
Page 16
EMS Ltd. Technology House Sea Street, Herne Bay, Kent, CT6 8JZ. +44 (0) 1227 369570 +44 (0) 1227 369679 www.emsgroup.co.uk ©2018 EMS Ltd. All rights reserved. Page 16 of 16 MK108 Iss4 27/07/2018 AJM...
This manual is also suitable for:
7258
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL