TroubleShooting Manual

Max call limit alarm

It is an alarm created when a certain percentage is reached on the basis of pre-
configured max call and max call threshold alarm.

Symptoms

On the iBG2016 system, following event will be occurred.
#Feb 09 11:57:45 critical
threshold of the system max call limit
#Feb 09 11:58:28 informational EVENT
threshold of the system max call limit
#Feb 09 11:59:23 error
threshold of the system max call limit
#Feb 09 11:59:25 informational EVENT
threshold of the system max call limit

Possible Causes

Current call count is reached on pre-configured threshold alarm value.
Minor threshold limitation value = system wide max calls * minor
threshold alarm max-call / 100
Major threshold limitation value = system wide max calls * major
threshold alarm max-call / 100