• Selection of the brake resistors at dynamic braking

The power on the brake resistor depends on the braking time and the duty factor. (Pnominal / 50 ÷ Pnominal)
The necessary power is determined by the braking time and the duty factor.
Frequency
Resulting
converter type
resistance
E3D 0.55 ÷ 1.1
E3D 1.5 ÷ 4
The brake resistors are imposed to high voltages of 660 V DC.
The appliance must be installed and wired very carefully because of heat developing and for proper
electric shock protection.
For wiring use cables with heat-resisting coating.
 MAINTENANCE
At normal operation the device needs no maintenance. Depending on the surroundings inspect regularly the
ventilators, and at models built in cabinet also the condition of the filter cartridge.
Inspect the screwed fastenings according to the local maintenance regulations, but at least once a year.
 GUARANTEE AND REPAIR
The products come with a guarantee period of 24 months.
The guarantee covers normal operation only.
In case of improper storage, improper use or unauthorized intervention the guarantee terminates.
Repair will be accomplished both within the guarantee period and after in the manufacturer's premises, the
appliance has to be transported there by the user.
Potentio-
meter
1
2
3
≥ 200 Ω
≥ 100 Ω
▪ 100 W wire-wound
resistors
(50÷200 Ω)
1 2 3
▪ 500 W wire-wound
resistors
(50÷100 Ω)
8
CAUTION
8
CAUTION
- 16 -
0,55 ÷ 4 kW
▪ 2÷4 kW cased brake
resistor modules
(12,5÷100 Ω)

Advertisement

Table of Contents
loading

This manual is also suitable for:

E3d 2.2E3d 1.1E3d 1.5E3d 3E3d 4E3d 0.75

Table of Contents