Centrometal Cm Pelet-set 90 Technical Instructions
Centrometal Cm Pelet-set 90 Technical Instructions

Centrometal Cm Pelet-set 90 Technical Instructions

Hide thumbs Also See for Cm Pelet-set 90:

Advertisement

CENTROMETAL d.o.o. – Glavna 12 – 40306 Macinec – Croatia
tel: +385 40 372 600; fax : +385 40 372 611
TECHNICAL INSTRUCTIONS
FOR THE COMMISSIONING AND ADJUSTMENT
Cm Pelet-set - touch
(60-90 kW)
For boilers:
EKO-CK P 70-110
TUPS-90-T-07-2017-E-N-eng_1.07

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Cm Pelet-set 90 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Centrometal Cm Pelet-set 90

  • Page 1 CENTROMETAL d.o.o. – Glavna 12 – 40306 Macinec – Croatia tel: +385 40 372 600; fax : +385 40 372 611 TECHNICAL INSTRUCTIONS FOR THE COMMISSIONING AND ADJUSTMENT Cm Pelet-set - touch (60-90 kW) For boilers: EKO-CK P 70-110 TUPS-90-T-07-2017-E-N-eng_1.07...
  • Page 2: Table Of Contents

    1. Introduction ...…………………………………………………………………………………………….. 2. Status at delivery ………………………………………………………………………………………… 3. Technical data …………………………………………………………………………………………… 4. Installation of Cm Pelet-set 90.……………………………………………………………..………….. 4.1. Installation of pellet burner and pellet control unit on boiler ..……………..…………... 4.2. Installation of pellet tank CPSP-800 and pellet feeder CPPT-90…………………..…..
  • Page 3: Introduction

    Technical instructions for the commissioning and adjustment 1. Introduction Cm Pelet-set 90, pellet based heating system (nominal burner output 60 to 90 kW) designed for installation in combined boilers or biomass firing boilers EKO-CK P, with thermal output from 70 to 110 kW.
  • Page 4 Technical instructions for the commissioning and adjustment Cm Pelet-set 90 on boilers EKO-CK P Cm Pelet-set type Burner CPPL type CPPL-90 CPPL-90 CPPL-90 Set thermal output (kW) Boiler type EKO-CK P 70 EKO-CK P 90 EKO-CK P 110 Pellet tank volume...
  • Page 5: Installation Of Cm Pelet-Set

    Technical instructions for the commissioning and adjustment 4. Installation of Cm Pelet-set 90 Commissioning and fine adjustment of Cm Pelet-set 90 should be carried out by a professional or the manufacturer’s authorized fitter. 4.1. Installation of pellet burner and pellet control unit on the boiler...
  • Page 6 Technical instructions for the commissioning and adjustment...
  • Page 7 Technical instructions for the commissioning and adjustment c) Drill 2 holes at the distance of 358 mm on the top side of boiler plating, and using enclosed screws 3.9 x 9.5 mm fix boiler control unit CPREG - touch, insert the safety thermostat sensor and control unit sensor into the sleeve on the boiler (on the top side on EKO-CK P boiler) and connect wires by 4-poles and 6-poles connectors onto the burner and then fix the connectors to the burner body.
  • Page 8: Installation Of Pellet Tank Cpsp-800 And Pellet Feeder Cppt-90

    Figure 1a. Connection scheme of the boiler EKO-CK P 70, 90 and 110 with in-built Cm Pelet-set 90 on heating installation with stainless steel hot water boiler: 1. Boiler EKO-CK P 70, 90,110 with in-built Cm Pelet-set 90 2. Stainless steel hot water boiler TB 3.
  • Page 9: Start/Stop

    (see Technical instructions EKO-CK P or EKO-CKB P) or a chimney with the following minimum draughts has to be select for certain powers: Cm Pelet-set 60 = 24 Pa Cm Pelet-set 70 = 25 Pa Cm Pelet-set 90 = 28 Pa...
  • Page 10: Automatic Pellet Refill

    Technical instructions for the commissioning and adjustment 7. Automatic pellet refill – additional equipment Main switch – on/off power supply for the filling system LED – main switch – on when there is power supply Operation mode switch – select working mode: 0 –...
  • Page 11: Initial Setting Of The Regulation

    Technical instructions for the commissioning and adjustment 8. Initial setting of the regulation 8.1. Setting the configuration 1. In main screen press “Menu” button 2. In “Main” menu press “Installation” button (SERVICE PIN required) 3. In “Installation” menu press “Commissioning” 4.
  • Page 12: Setting The Protection Valve Actuator Time

    Centrometal d.o.o. shall not be responsible for possible incorrect data caused by printing errors or errors during transcription and in any case, it reserves the right to modify its products deemed to be required and useful, without any prior notification 1.07...