Danfoss PVG 32 Application Manual page 11

Using flow or pressure control spools
Hide thumbs Also See for PVG 32:
Table of Contents

Advertisement

Application Guide
Using flow or pressure control spools
Summary
©
Danfoss | Feb 2017
In certain applications, you can use a PVG with a pressure control (PC) spool instead of a traditional flow
control (FC) spool. The PC spool provides a dampening effect on natural oscillations because the PC spool
maintains a constant pressure on the work port while allowing a variable flow, depending on changes in
the work port load.
A situation in which PC spools are of great value is when you are lowering a load in an application that
uses counterbalance (CB) valves. A combined FC and PC spool, with the FC in the lifting port and the PC
in the lowering port, results in optimal controllability.
AB00000079en-US0101 | 11