Troubleshooting - CMP PowerClean Salt Econ Installation Instructions & Product Manual

Table of Contents

Advertisement

E. TROUBLESHOOTING
SITUATION
Low or no chlorine residual
in pool
Unable to increase chlorine
production
The cell housing is leaking
from the cap (bottom of
cell cap or through the cord
hole)
Water is leaking from the
cell plug.
16
POSSIBLE CAUSE
Low stabilizer (Cyanuric acid level in
pool water).
Insufficient run time.
Chlorine Output percentage set too
low.
Recent increases in weather
temperature without increasing the
Chlorine Output of the system
Temporary loss of chlorine due to
heavy rain, leaves, fertilizer or heavy
bather load, recent party, or pets using
pool.
Loss of salt due to rain or added water.
Low salt level (less than 3,000 PPM).
System Power light is flashing/ service
light is yellow/ solid.
Cold water, low salt level, or cell is over-
calcified
O-ring may be improperly seated.
Cell cap may be cross threaded.
Water is traveling through a crack in
the cell base and up the cell cord.
CORRECTIVE ACTION
Add stabilizer to maintain 20-30 PPM per
pool professional's recommendations.
Increase daily run time. Recommend 1
hour of run time per 10 degrees ambient
temp.
Increase the Chlorine Output Level (see
page 13 ).
Increase the Chlorine Output Level (see
page 13).
Set Chlorine Output to BOOST (Super
Chlorinate) for 72 hours. Re-check- if still
too low, superchlorinate with outside
source. (Take pool water sample to pool
professional)
Test salt level. Add salt using the chart on
page 11
Increase salt level by adding salt according
to chart on page 11.
Check cell and clean, check salt
level, check water temperature.
Confirm that o-ring has not been
lubricated. Clean the o-ring slot of any dirt
or debris. Fully seat the o-ring in into the
slot before inserting the cell back into the
housing.
Unscrew cap and confirm that
the cap screws onto the housing
without resistance.
Contact Tech Support