INVERTER MANUAL
INT-300/600/1000/1500
Äkta sinusvåg / pure sine wave
INT-300
INT-600
INT-1000
INT-1500

Advertisement

loading
Need help?

Need help?

Do you have a question about the INT-300 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for CMP INT-300

  • Page 1 INVERTER MANUAL INT-300/600/1000/1500 Äkta sinusvåg / pure sine wave INT-300 INT-600 INT-1000 INT-1500...
  • Page 2 Vid felaktig användning så aktiveras inbyggda skyddsfunktioner och en in- DC system som har den positiva polen ansluten till fordonets chassi. byggd summer ljuder vid vissa fel situationer. INT-300/600 är utrustade med en 1. Kontrollera att invertern är avstängd, 0 - I strömbrytaren är satt i läge (0).
  • Page 3 Dålig kontakt vid anslutningarna kan ge låg eller helt utebliven spänning. Kontrollera därför anslutningarna mellan invertern och den anslutna utrust- Till samtliga modeller kan en remote panel anslutas. För INT-300/600 är det ningen samt att batteriet är tillräckligt laddat. Remote 1 som har on/off funktion (motsvarande inverterns inbyggda ström- •...
  • Page 4 Tekniska data: 300W och 600W modellerna Tekniska data: 1000W och 1500W modellerna Modell Modell INT-300-12 INT-300-24 INT-600-12 INT-600-24 INT-1000-12 INT-1000-24 INT-1500-12 INT-1500-24 Inspänning 10-16 VDC 20-32 VDC 10-16 VDC 20-32 VDC Inspänning 10-16 VDC 20-32 VDC 10-16 VDC 20-32 VDC...
  • Page 5: English Version

    INVERTER MANUAL English version CMP är ett registrerat varumärke hos Powermec AB www.powermec.se...
  • Page 6 The inverters are equipped with protection against wrong usage or connec- Therefore, never use the inverter in a positive (+) DC ground system as they tion and a buzzer will sound in some situations. INT-300/600 is equipped with a have the positive pole connected to chassis.
  • Page 7: Troubleshooting

    • Measure the output voltage from mains socket with a ”TRUE RMS” meter. To all models it’s possible to connect and use a Remote panel. For INT-300/600 • Check the fuse (valid only for the 300W model). For all other models the it’s Remote 1 with on/off function (similar function to the on/off switch on the inver-...
  • Page 8 Technical data: 1000W and 1500W models Technical data: 300W and 600W models Model Model INT-300-12 INT-300-24 INT-600-12 INT-600-24 INT-1000-12 INT-1000-24 INT-1500-12 INT-1500-24 Input voltage 10-16 VDC 20-32 VDC 10-16 VDC 20-32 VDC Input voltage 10-16 VDC 20-32 VDC 10-16 VDC...
  • Page 9 CMP is a registered trademark at Powermec AB www.powermec.se...