ABB LMT Series Operating Instruction page 80

Magnetostrictive level transmitters foundation fieldbus
Hide thumbs Also See for LMT Series:
Table of Contents

Advertisement

80
L M T 1 0 0 A N D L M T 2 0 0 | M A G N E TO S T R I C T I V E L E V E L T R A N S M I T T E R S | F F O I/ L M T 1 0 0/ 2 0 0/ F F - E N R E V. A
LMT200 Cryogenic with insertion well - Top Mount
*Drawings for Reference Only
Vibration Isolator Mount Option
Kit Includes:
1 Vibration Isolator
1 Chamber mounting clamp assembly
2 Bearing clamp assemblies
For measurement lengths (ML) of 914 4mm (36in) or less, a
minimum of two VI-KIT assemblies are recommended for
installation in high vibration applications
For ML greater than 914 4mm (36in), the number of isolators
required can be determined from the below chart
ML up to
914.4mm (36in)
1828.8mm (72in)
2286.0mm (90in)
2743.2mm (108in)
3200.4mm (126in)
3657.6mm (144in)
4114.8mm (162in)
4572.0mm (180in)
> 4572.0mm (180in)
# of Kits
2
3
4
4
5
5
6
6
consult factory