olympia electronics BS-850/T Manual

Wireless programmable wifi chrono -thermostat with heating function - battery operated with boiler output

Advertisement

BS-850/KIT, BS-851/KIT
BS-850/KIT, BS-851/KIT
BS-850/T - BS-851/T
BS-850/R - BS-851/R
The key
on the BS-850/T.
28
27
26
1
2
3
4
5
6
7
8
Page 1 from 13
WIRELESS PROGRAMMABLE WiFi CHRONO - THERMOSTAT
WIRELESS PROGRAMMABLE WiFi CHRONO - THERMOSTAT
WITH HEATING FUNCTION - BATTERY OPERATED WITH BOILER
WITH HEATING FUNCTION - BATTERY OPERATED WITH BOILER OUTPUT
Wi
Thank you for your trust in our products
Olympia Electronics - European manufacturer
is like this
25
24
23
22
21
MENU
ENTER
ESC
9
10
11
12
13
14
● Wireless connection between thermostat and
commands of Relay.
● Connection with WiFi.
● Controlled from the smartphone.
● RF signal strength indicator.
● 3 operation modes: manual, daily and weekly.
● 8 key easy operation.
● Easy programm entry.
● Multiply indication screen with backlight.
● Clock, Calender.
● Keypad lock
● Selection of upper and lower limits for
manual temperature selection.
● Boiler operation (BS-851/Τ) with selectable time.
● Easy connection - adjustment.
Only for BS-851/R
CONTROL AND INDICATIOR
DESCRIPTION
Thermostat activation
1
Thermostat deactivation
2
Increase value
3
Decrease value
4
Presence indicator
5
Thermostat active
6
Thermostat inactive
7
20
Battery state indicator
8
19
Ascending or descending temperature
9
18
indicator
17
= When the selection is less than the
actual temperature.
16
= When the selection + the differential is
15
more than the actual temperature.
= When the temperature is between the
selection and the selection
differential.
OUTPUT
the
+
940851000_09_001

Advertisement

Table of Contents
loading

Summary of Contents for olympia electronics BS-850/T

  • Page 1 ● Boiler operation (BS-851/Τ) with selectable time. ● Easy connection - adjustment. Only for BS-851/R BS-850/R - BS-851/R Thank you for your trust in our products Olympia Electronics - European manufacturer CONTROL AND INDICATIOR DESCRIPTION The key is like this Thermostat activation on the BS-850/T.
  • Page 2 MENU ENTER BOILER BURNER POWER/ OPERATION Hour and message display Temperature and message display Temperature units display Active burner output display Selecting on not the area presence program Escape from a selection Activate / Deactivate boiler (valid only for the BS-851/T) Go to the next item or selection Select normal or night program Go to the previous item or selection...
  • Page 3: Table Of Contents

    CONTENTS CONTENTS Setting up the device, page 3 Screen illumination, page 7 Entering the MENU, page 5 Burner output indicator, page 7 Day or Night operation, page 5 Manual operation time, page 7 Boiler activation selection, page 5 Differential value, page 7 Presence selection, page 5 Hour meter, page 8 Keypad lock, page 6...
  • Page 4 5) To set up the parameters of WiFi you can do this either selecting WPS either Smart Config (Figure 5): By WPS Ÿ Push the WPS button (Figure 1) and the r e c e i v e r g e t s i n W P S m o d e . Subsequently you have to push the WPS button on the router as shown in your smartphone’s screen (Figure 6).
  • Page 5: Entering The Menu

    temperature is set to 18.0ºC. To deactivate GENERAL the night program, press the key for When the plastic battery separator is more than 3", the symbol is replaced by removed the unit is automatically activated the symbol and shows all the screen indicators for 1",then the firmware version is shown and 3.
  • Page 6: Keypad Lock

    5. KEYPAD LOCK (in any operation state). blinking . With consecutive presses of MENU If the keys are pressed key you can select the remaining ENTER MENU simultaneously for 3" (first the key and programs of the 24 hour cycle (10 in total) ENTER then the ), the screen will show the...
  • Page 7: Setting The Limits Of The Manual Program

    The option are: (Degree for all the 24 hour base. Celsius ή Degree Fahrenheit) and regard 9. SELECTING THE UPPER AND LOWER the display of the temperature in ºC or ºF. L I M I T S T H E M A N U A L TEMPERATURE ADJUSTMENT (the Depending on the selection, the symbol ºC...
  • Page 8: Hour Meter

    The differential value can be set between 12. ANTI-ICE PROTECTION 0.2 °C and 4.0 °C. If the room temperature in which the The factory default value is 0.2 °C. thermostat is installed falls below 5°C, the (Heat/Cold). HEATING MODE. unit activates the burner output irrelevant of The device can control only heating the ON or OFF state of the thermostat to units (e.g.
  • Page 9: Daily Programming Example

    MENU FACTORY DEFAULT VALUES 4. Press the key and the starts to ENTER The following values are the factory default blink. With the keys select setting of the thermostat: the operation mode (Day - daily Thermostat state = Inactive (OFF) program).
  • Page 10: Weekly Programming Example

    correctly make sure you have programmed device clock with the correct time. the device clock with the correct time. WEEKLY PROGRAMING EXAMPLE. WIRELESS CONNECTION SETTING The weekly program in general is based on After installing the peripheral received (BS- the daily programming which is repeated for 851/R), press the programming key (Figure every day of the week independently.
  • Page 11: Communication Errors

    COMMUNICATION ERROR Errors can occur if for any reason the communication between the two devices is disrupted. The screen of the thermostat will show the message (Communication Error), the backlight of the screen will blink. The interruption of the mains voltage causes the interruption of communication between the two devices.
  • Page 12 Installation procedure Installation procedure To install the devices BS-850/T or BS-851/T, insert a flat blade screwdriver in the slot as shown in (Fig. 1). Press and lift the front cover. Remove the retaining screws and remove the plastic cover that contains the keys (Fig. 2).
  • Page 13 Olympia Electronics or if the buyer modifies the goods provided or has any repairs or re-setting done by a third party, unless Olympia Electronics has fully agreed to them in writing. Products that have been damaged can be returned to the premises of our company for repair or replacement, as long as the warranty period is valid.

This manual is also suitable for:

Bs-851/tBs-850/rBs-851/r

Table of Contents