BS-844/2
OPERATION VOLTAGE
CONSUMPTION (only the device)
OUTPUT POWER FOR THE FAN
OUTPUT POWER FOR THE CIRCULATOR
OUTPUT PROTECTION FOR BLOWER/CIRCULATOR
SMOKE SENSOR MEASUREMENT RANGE
WATER SENSOR MEASUREMENT RANGE
BLOWER POWER ADJUSTMENT
SENSOR CABLE LENGTH
SENSOR CONSTRUCTION MATERIAL
DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH
OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY
EXTERNAL DIMENSIONS
TYPICAL WEIGHT (main unit / + sensor)
GUARANTEE
(6)
POWER
( ) 7
CIRC.
(8)
Θερμοστάτης ξυλολέβητα
(1)
(4)
(3) (2)
CONTROL AND INDICATOR DESCRIPTION
(1). ON/OFF button
(2). Settings selection button
(3). Decrease selected setting button
(4). Increase selected setting button
(5). LED information display
(6). Mains power indicator
(7). Circulator operation indicator
(8). Fan operation indicator
BASIC SETTINGS
When the unit is powered for the first time all the
indicators and the LED display are lit. After that a
factory number is shown and the unit goes to a
standby state. The display shows
Here we can adjust the required setting
depending on the type of wood burner. To enter
the settings adjustment menu we must press
continuously the button
the display shows the message
Immediately after pressing one of the keys (+) and
(-), the display will scroll all the programming
Page 1 from 7
Programmable recessed thermostat for wood burners
with connection ability of two sensors
TECHNICAL CHARACTERISTICS
(5)
MENU
.
for a few seconds until
.
220-240V AC/45-55Hz
3VA / 2,5W maximum
200W maximum
15
0W maximum
Replaceable fuse
-40 C to 120 C
200 centimeters
for water: nickel-plated brass, for smoke: stainless steel
EN 60730-1, EN 60730-2-9, EN 61000-6-1, EN 61000-6-3
-10 to 60 C
0 - 90% RH
137 x 95 x 45 mm
275gr / 425gr
parameters of the device. When the desired
parameter is displayed by pressing the MENU
button the initial value can be changed to the
desired value using the (+) and (-) buttons.
Whichever of the buttons (+) or (-) is pressed
constantly, changes the value quickly, not
requiring repeating presses.
If the MENU button is pressed again, the value is
stored in the device memory and the display
shows the name of the parameter that you just set.
Below are the programming parameters as would
occur if the button (+) is repeatedly after
message
1. Circulator start temperature setting
The display shows the message
Start Temperature). Pressing the MENU button
will show the factory default setting which is 45ºC.
This value can be adjusted from 35–60ºC and sets
the water temperature above which the circulator
starts to operate. If the water temperature is lower
then the selected value then the circulator does
not operate.
2. Safety level temperature adjustment.
The display shows the message
Limit). Pressing the MENU button will show the
factory default setting which is 85ºC. This value
can be set between 86°C and 95ºC and
determines the overheating level of the water.
If the water temperature exceeds this level then
the message
and the buzzer is activated with an intermitted
sound.
(0
,85A
)
(0 6
, 5A
)
o
0-450 C
o
o
0-100%
IP20
o
2 years
is shown:
(High Temperature) is shown,
940844002_09_004
the
(Circulator
(Over Heat