Dimensional drawing (mm)
33
90
C
NO
58
82
WARNING HEALTH AND SAFETY INFORMATION
!
National safety regulations
!
Failure to comply with national safety regulations may result in
personal injury, discomfort, property damage and other potential
hazards.
Comply with any national regulations and comply with
Ÿ
appropriate safety regulations
You shall comply with any additional national regulatory
Ÿ
informations.
Risk of electric shock
Disconnect the power supply prior installation of the thermostat.
WARNING! installation, configuration, start-up and maintenance
must be done by qualified personnel only.
The device is considered an electronic device for disposal in
accordance with the European Guidelines and may not be disposed of
as domestic garbage.
Dispose of the device through channels provided for this purpose.
Ÿ
Ÿ
Comply with all local and currently applicable laws and regulations.
Dispose of empty batteries in designated collection points.
Ÿ
4
TECHNICAL CHARACTERISTICS
OPERATING VOLTAGE
FREE RELAY CONTACT
ADJUSTMENT TEMPERATURE
DIFFERENTIAL
ANTI-FREEZE PROTECTION
90
CALIBRATION
DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH
RELATIVE HUMIDITY
EXTERNAL DIMENSIONS
CONSTRUCTION MATERIALS
COLOR
TYPICAL WEIGHT (including batteries)
WARRANTY
WARRANTY
Olympia Electronics guarantees the quality, condition and operation of the
goods. The period of warranty is specified in the official catalogue of Olympia
Electronics and also in the technical leaflet, which accompanies each product.
78
This warranty ceases to exist if the buyer does not follow the technical
instructions included in official documents given by Olympia Electronics or if
the buyer modifies the goods provided or has any repairs or re-setting done
by a third party, unless Olympia Electronics has fully agreed to them in
writing. Products that have been damaged can be returned to the premises
of our company for repair or replacement, as long as the warranty period is
valid.
Olympia Electronics reserves the right to repair or to replace the returned
goods and to or not charge the buyer depending on the reason of defection.
Olympia Electronics reserves the right to charge or not the buyer the
transportation cost.
5
940830000_09_001
BS-830
BS-830/C
2 Alkaline batteries ΑΑ (LR06)
5Α (3) - 250V AC
o
5 to 35 C
o
0.2 C
o
4.5 C
+ -
o
3.0 C
IP20
EN 61000-6-1, EN 61000-6-3,
EN 60730-1, EN 60730-2-9
0 - 90% RH
90 x 90 x 33mm
ABS/PC, PC
WHITE
ANTHRACITE
180gr
2 years
72nd km. O.N.R. Thessaloniki-Katerini
P.C. 60300 P.O. Box 06 Εginio Pierias Greece
www.olympia-electronics.com
info@olympia-electronics.gr
940830000_09_001
European
manufacturers
DIGITAL ELECTRONIC THERMOSTAT
Thank you for your trust in our products
Olympia Electronics - European manufacturer

Advertisement

loading

Summary of Contents for olympia electronics BS-830

  • Page 1 Olympia Electronics or if the buyer modifies the goods provided or has any repairs or re-setting done by a third party, unless Olympia Electronics has fully agreed to them in writing. Products that have been damaged can be returned to the premises of our company for repair or replacement, as long as the warranty period is valid.
  • Page 2 Package Contents Installation 1 x Thermostat 1 x Termostat mounting base 1 x Mounting accessories 2 x Alkaline batteries ΑΑ Operational Information Remove the battery protective film. Burner indication Low battery temperature indicator Current Burner indicator temperature Decrease Increase temperature key temperature key BEFORE THE INSTALLATION Remove the protective film which is located in the right battery (Figure 2), the...

This manual is also suitable for:

Bs-830/c