olympia electronics BS-820/KIT Manual

olympia electronics BS-820/KIT Manual

Battery operated wireless programmable chrono-thermostat with cooling and heating function

Advertisement

Quick Links

BS-820/KIT
BS-820/KIT
BS-818/T - BS-819/T
BS-820/R
Olympia Electronics - European manufacturer
The key
on the BS-818/T.
28
27
26
1
2
3
4
5
6
7
8
Page 1 from 11
BATTERY OPERATED WIRELESS PROGRAMMABLE
BATTERY OPERATED WIRELESS PROGRAMMABLE
CHRONO-THERMOSTAT WITH COOLING AND HEATING FUNCTION
CHRONO-THERMOSTAT WITH COOLING AND HEATING FUNCTION
Thank you for your trust in our products
is like this
25
24
23
22
21
MENU
ENTER
ESC
9
10
11
12
13
14
Wireless connection between the thermostat
and the Relay.
RF signal strength indicator.
3 operation modes: manual,
daily, weekly.
8 key easy operation.
Easy program entry.
Multi indication screen with back light.
Clock, Calender.
Keypad lock.
Selection of upper and lower limits for
manual temperature selection.
Boiler operation (BS-819/T) with selectable time.
Heating and Cooling function.
Easy connection - adjustment.
CONTROL AND INDICATOR DESCRIPTION
. Thermostat activation
1
. Thermostat deactivation
2
. Increase value
3
. Decrease value
4
. Presence indicator
5
. Thermostat active
6
20
. Thermostat inactive
7
19
. Battery state indicator
8
18
. Ascending or descending temperature
9
17
indicator
= When the selection is less than the
16
actual temperature.
15
= When the selection + the differential is more
than the actual temperature.
= When the temperature is between the
πππ
selection and the selection
οΠΠ
the differential.
+
940820001_09_001

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BS-820/KIT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for olympia electronics BS-820/KIT

  • Page 1 Boiler operation (BS-819/T) with selectable time. Heating and Cooling function. Easy connection - adjustment. BS-820/R Thank you for your trust in our products Olympia Electronics - European manufacturer CONTROL AND INDICATOR DESCRIPTION The key is like this on the BS-818/T.
  • Page 2 MENU ENTER BURNER POWER/ STATUS Hour and message display Temperature and message display Temperature units display Active burner output display Selecting on not the area presence program Escape from a selection Activate / Deactivate boiler (valid only for the BS-819/T) Go to the next item or selection Select normal or night program Go to the previous item or selection...
  • Page 3: Entering The Menu

    the night program, press the key for GENERAL more than 3", the symbol is replaced by When the plastic battery separator is the symbol remove the unit is automatically activated 3. Boiler ACTIVATION (available only on and shows all the screen indicators for the BS-819/T).
  • Page 4: Setting The Time And Date

    Which ever key is pressed after this will require a temperature of 23.0 ºC from show the same message on the screen. 14:00 to18:00 in program 1 we will set the All other function are executed normally. start time 14:00 at 23.0 ºC and the start time To unlock the keypad follow the same of the second program 18:00 with the procedure and the screen will show the...
  • Page 5 illumination in order to conserve battery be shown on the bottom of the screen as well as the initial value 30.0 ºC. By energy. If (ΟΝ) is selected then the screen illumination will be activated every pressing the key we can change this MENU ENTER time a key is pressed.
  • Page 6 control heating units (e.i. diesel burners), 12. ANTI-ICE PROTECTION whereas with the selection it can If the room temperature in which the c o n t r o l c o o l i n g u n i t s ( e . i . a i r - thermostat is installed falls below 5°C, the conditioners).
  • Page 7 FACTORY DEFAULT VALUES blink. With the keys we select The following values are the factory default the operation mode (Day - daily setting of the thermostat: program). Thermostat state= Inactive (OFF) 5. Press the key and we return to the Daily and weekly programs = Not set previous screen with the blinking.
  • Page 8 WEEKLY PROGRAMING EXAMPLE. WIRELESS CONNECTION SETTING The weekly program in general is based on This procedure is required for every new the daily programming which is repeated for installation in order to establish the every day of the week independently. For communication and to verify the quality of the days of the week that have not been the signal.
  • Page 9 COMMUNICATION ERROR Errors can occur if for any reason the communication between the two devices is disrupted. The screen of the thermostat will show the message (Communication Error), the backlight of the screen will blink. The interruption of the mains voltage causes the interruption of communication between the two devices.
  • Page 10 Installation procedure Installation procedure To install the devices BS-818/T or BS-819/T, insert a flat blade screwdriver in the slot as shown in (Fig.1). Press and lift the front cover. Remove the retaining screws and remove the plastic cover that contains the keys (Fig.2). Use the supplied mount accessories to mount the unit according to the diagram of page 10.
  • Page 11: Technical Characteristics

    Olympia Electronics or if the buyer modifies the goods provided or has any repairs or re-setting done by a third party, unless Olympia Electronics has fully agreed to them in writing. Products that have been damaged can be returned to the premises of our company for repair or replacement, as long as the warranty period is valid.

This manual is also suitable for:

Bs-821/kitBs-818/tBs-819/tBs-820/r

Table of Contents