The control of preservation of the
flexible pipe consists in checking that:
- it doesn't show cracks, cuts, marks of
burnings both on the end parts and on
its full extent;
- the material is not hardened, but shows
its normal elasticity;
- the fastening clamps are not rusted;
- expiry term is not due.
If one or more abnormalities are seen,
do not repair the pipe, but replace it.
IMPORTANT
Once installation is complete,
check the perfect seal of every pipe
fitting, using a soapy solution, never
a flame.
IMPORTANT
The replacement/conversion of
the appliance should only be
undertaken by a registered
engineer or competent person.
It is important to note that this model
is designed for use with natural gas
G20 20 mbar but it can be
converted for use with natural gas
G20 13 mbar (only for Russia) or
liquid gas G30 30 mbar providing
the correct injectors are fitted. The
gas rate is adjusted to suit.
Adaptation to different kinds of
gas
To adapt the appliance to a different
kind of gas from the one the appliance
has been set for, follow the instructions
below in their order.
Hob burners nozzles replace-
ment
1. Remove the pan supports.
2. Extract the caps and the wall baffles
of the burners.
Gas pipeline