1. Pump Use
ATD vacuum pumps are designed to obtain vacuum by pumping gas from sealed
containers. They are suitable for use with R12, R22 and R134a air conditioning
systems, as well as medical appliances, printing machinery and vacuum packing.
They can be continuously used at 5℃ to 40℃
2. Features
Oil Anti-flowback Design
The gas inlet is specially designed to prevent the oil from flowing back, preventing the
container being pumped as well as the hoses from becoming polluted.
Environmental Design
The tank has separating devices at the exhaust port to prevent oil-spraying and to
reduce pollution.
Aluminum Alloy Casing
The ATD vacuum pump is manufactured with an aluminum alloy casing.
Because aluminum has good heat dissipation qualities, it will help to keep the pump
running more efficiently for a longer period of time.
Overall Design
The electric machinery and the pump are designed to make the product compact and
lighter.
EXPERTS IN VACUUM PUMPS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ATD-3425 and is the answer not in the manual?

Questions and answers

Summary of Contents for ATD Tools ATD-3425

  • Page 1 As a specialized enterprise in making vacuum pumps, we have devoted ourselves to satisfy our customers’ need for high quality products. We adopt the latest designs and technology to make sure that our products not only use less energy, produce less noise and last longer but also to ensure that they have the best design for the environment and for reducing pumped gas pollution.
  • Page 2: Product Illustration

    Easy to start, Faster to pump The starter design makes the ATD vacuum pump easy to start even in lower temperatures. This feature allows higher efficiency and faster pumping. Low Noise and Vibration An elastomeric coupling insert between the motor and module results in extremely quiet and smooth operation.
  • Page 3 4. User’s Manual ·Examine the oil-level before using to make sure the oil-level is not lower than the oil-level line in the sight glass. DO NOT RUN PUMP WITH LOW OIL LEVELS. Add oil to bring it up to the oil level line. This pump uses high-speed vacuum oil HFVM200 or equivalent.
  • Page 4: Installation

    outlet. ·When unplugging the pump, pull the plug. Don’t unplug unit by pulling on the wire. ·Keep electrical cord free from all shop equipment, and do not let pump hang power cord ·Don’t use damaged plug or outlet. ·Don’t plug or pull out the plug with wet hands. ·Don’t plug unit in, unplug unit or use switch if there are any flammable or explosive gases present.
  • Page 5: Maintenance

    Problem Possible Cause Correction Low Degree 1. Lack of oil 1. Add oil to above the oil level line of Vacuum 2. Oil is not clean 2. Change the oil 3. The oil inlet is blocked 3. Clean the oil inlet or clean the filter 4.
  • Page 6 ·Repair of pump should only be done by experienced repair facilities. 9. Technical Specifications Model: ATD-3425 Model Power Supply: 110V 60HZ Free Air Displacement: 5 CFM Number of Stages: 1 Stage...