1-6-4

MR Unit :Replacing the Filter Element (18000 hours)

4T3C-AC00
4T3C-025E
To the next page
4T3C-E-MMA01-A09-01
Replacing the Consumable Parts
1.
Turn off the power.
2.
Turn off the air.
3.
Pull out the valve upward and rotate it
to the left.
• Remaining air pressure is discharged.
• Return the valve to the original position.
443C-301P
443C-037E
4.
Loosen the bolt with the hexagonal
bolt. (4 bolts)
5.
Remove the case.
∗ Check that the O-ring is put on the case. If it is
taken out, fit it to the groove of the O-ring.
O-ring
Case