Program Initial Setting - Taie FY400 Operation Manual

Digital temperature controller
Hide thumbs Also See for FY400:
Table of Contents

Advertisement

13.3 Program Initial Setting

Program
Initial Setting
Program time format
Program execute
Program execute with
repeat function ?
Program execute with
power fail function ?
Program execute with
wait function ?
1.
Setting program time format
Parameter
SET9.2
This parameter determines the time format of timer during program execution
When SET9.2 =0 , TM_n=33.23, it indicates that the execution time of this segment is 33 hours and 23 minutes When
SET9.2 =1 , TM_n=33.23, it indicates that the execution time of this segment is 33 minutes and 23 seconds
2.
Setting program execute start address
Parameter
SET8.3
When program starts, SV initial value will execute according to SET8.3 set value
(1) SET8.3 =0, PTN=1 PV=50.0 SV_1=100 TM_1=1.00(1 hour)
When program starts, SV will start to execute from 0.0, and SV shall reach SV_1 in one hour
(2) SET8.3 =0, PTN=1 PV=50.0 SV_1=100 TM_1=1.00(1 hour)
When program starts, SV will start to execute from PV temperature of 50.0, while controller will deduct the time
taken to go from 0.0 to 50.0, and SV shall reach SV_1 in half hour
3.
Setting program execute with repeat function
Parameter
SET8.1
When program completes the execution of the final segment, and "END" message is not shown, the program will be
executed again.
4.
Setting program execute with power failure protection function
Parameter
SET8.2
power failure during program execution, if there is power failure protection function set,
controller will execute current segment program after booting finish
Assume power failure occurring in the segment_4, ramp temperature from 100°C to 200°C, and power failure
occurring at SV=125, the program will execute from 100°C (segment_4), after controller booting finish
49
start address
L
E
D
d
s i
p
a l
y
Program time format
0
:
h
o
u
. r
m
n i
u
e t
1 : minute.second
L
E
D
d
s i
p
a l
y
Program execute start address
0
:
e
x
e
c
u
e t
f
o r
1 : execute from current PV,cut time
L
E
D
d
s i
p
a l
y
Program execute repeat
0
:
d
s i
a
b
e l
e r
p
1 : Program execute repeat
L
E
D
d
s i
p
a l
y
Program execute power fail protection
0
:
d
s i
a
b
e l
p
o
1 : enable power fail protection
D
e
c s
i r
t p
o i
n
D
e
c s
i r
t p
o i
n
m
z
e
o r
D
e
c s
i r
t p
o i
n
e
t a
u f
n
t c
o i
n
D
e
c s
i r
t p
o i
n
w
e
f r
l i a
p
o r
e t
t c
o i
n
Default
Level
0
L
e
v
l e
4
Default
Level
1
L
e
v
l e
4
Default
Level
0
L
e
v
l e
4
Default
Level
0
L
e
v
l e
4
FY/FU operation manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fy600Fy700Fu400Fy900Fu48Fu86 ... Show all

Table of Contents