Adjusting The Booster - Schaudt Booster WA 121545 Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

8.4
8.4.1
Changing the battery
Setting
8200510 BA / EN
Operating Instructions Booster WA 121545

Adjusting the booster

Setting the battery type, "Batt. Type"
ATTENTION!
Y
Incorrectly setting the device or using unsuitable leisure area battery types
can damage the battery or devices connected to the leisure area battery. So
therefore:
Only ever have batteries changed by qualified personnel
F
Follow the battery manufacturer's instructions.
F
Only use the booster to connect to 12V power supplies with rechar-
F
geable 6 cell lead-gel, lead-acid, AGM batteries or lithium batteries.
Do not use any unsuitable battery types.
Normally only batteries of the same type and rating should be used, i.e.
Y
the same as those originally installed by the manufacturer.
It is possible to swap from lead-acid batteries to other battery types. Swit-
ching to lead-acid batteries is only possible in certain circumstances.
Contact the vehicle manufacturer for more information.
Once the battery has been changed, check again which battery type has
Y
been inserted and then ensure the battery type is set correctly.
DANGER!
Y
Incorrectly setting the battery type poses a risk of explosion (through the
formation of detonating gas).
Turn off the vehicle engine.
"
Briefly press the "Display" (Disp.) button -- Figure 11, Pos. 1.
"
The LED above the "Batt. Type" column lights.
F
The LED of the battery type currently set lights in the left-hand co-
F
lumn.
Within 6 seconds, press the "Set" button (Figure 11, Pos. 2) for longer
"
than 3 seconds.
The LED above the "Batt. Type" column flashes.
F
The LED of the battery type currently set flashes in the left-hand co-
F
lumn.
Keep pressing the "Set" button (Figure 11, Pos. 2) until the LED of the
"
battery type required flashes:
Battery
Charge voltage
type used
Lead-acid batteries
Lead-gel batteries
AGM1 batteries
AGM2 batteries
Lithium batteries
Voltage values apply when no temperature sensor is connected
or (with temperature sensor) at 25 C
* Only LiFePo4 batteries may be charged which have their own battery management system.
Date: 21.09.2017
Trickle charge
voltage
14.4 V
13.4 V
14.4 V
13.8 V
14.7 V
13.7 V
14.4 V constant (Curve CCCV)*
Switchover cur-
Max.
rent for
time phase
trickle charge
(delayed)
4 hours
Approx. 2.5 A
8 hours
Approx. 2.5 A
4 hours
Approx. 2.5 A
19

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents